Smart Energy Hot Water Specifications
(Australia)
ELECTRICAL SERVICE
Operating Voltage Range
207 - 264
Vac
AC Frequency
50
Hz
Nominal Voltage
230
Vac
Supported Grids
L/ N/ PE
Maximum Supported Load Size
4.8
kW
Maximum Load Current Rating
21
A
Minimum Output Power
5% of load rating
Load Type
Resistive
Efficiency
> 98
%
Input
Over-voltage
Protection
(1)
264
Vac
Output
Over-current
Protection
2
2
A
External Over-current Protective
Device Rating
≥
25
A
Type of Action
Type 1 C
Over Voltage Category
(2)
III
COMMUNICATION
Supported Communication
Protocol
ZigBee Home Automation
Device Configuration
Via the inverter LCD, the monitoring
platform/ app, or SetApp; Ethernet
connection is required
Nominal
Transmit
Power
11
.8
dBm
EIRP with Antenna
16
.8
dBm
Maximum Emitted Power
≤
2
0
dBm
Bandwidth
2
MHz
Modulation
O-QPSK with DSSS coding
Operating Frequency Range
2.4 - 2.5
GHz
Outdoor (LOS) Range
400 / 1312
m / ft.
(1)The device stops diverting power to the load when this threshold is exceeded
(2)Working voltage of 300 Vac.
1
Smart
Energy
Hot
Water
Specifications
MAN-01-0057
3
-1.
1
Содержание Smart Energy Hot Water
Страница 1: ...Installation Guide Smart Energy Hot Water Version 1 4...