Chapter 4: Installing the AC/DC Safety Switch
SolarEdge Installation Guide – MAN-01-00002-1.7
22
Opening Conduit Knockouts
1
Move the switch to the OFF position.
2
Loosen the screws on the front cover of the AC/DC Safety Switch, as shown below:
Figure 12: Opening the AC/DC Safety Switch Cover
3
Remove the AC/DC Safety Switch cover.
4
Open the AC and DC conduit knockouts: The switch has knockouts located at the bottom, back and
sides of the enclosure, each with two sizes: ¾'' and 1''. Open the necessary pair according to the
conduits used in the installation. For DCD-1ph-US-C Safety Switch, a Unibit drill may be used.
Mounting the AC/DC Safety Switch
1
Use the supplied template to mark the drilling hole positions: Align the top of the paper with
the bottom of the inverter mounting bracket and mark the drilling locations.
Figure 13: Template Position
Use at least two bracket holes. Additional holes can be used to stabilize the bracket. Determine
which and how many holes to use according to mounting surface type and material.
2
Drill the holes and connect the bracket.
Verify that the bracket is firmly attached to the mounting
surface.
3
Unscrew the two nuts at the conduit ends.
Loosen these
screws
DCD-1ph-US-B Safety Switch DCD-1ph-US-C Safety Switch
Paper
Template