3.2.4.3.
A good indication that the system is correctly wired and
configured is when the port monitor displays a steadily
increasing value for both TX packets and RX packets. Errors,
overruns and dropped packets are an indication of an issue
with the cabling, cable terminations, inverter CAN BUS
interface settings or battery CAN BUS interface setting.
3.2.5.
Victron GX Data from the battery
49