SECTION ONE INSTALLATION
LIST OF COMPONENTS
1) Hot box with brass trim
2) 22" HOT BOX Burner Unit
3) Ceramic Pieces 12
4) Black Coals-17 large 7 triangular.
5) User/Installation Instructions
6) Guarantee Card
7) Fire front and Fret
INSTALLATION INSTRUCTIONS
1) APPLIANCE DATA
Gas Category
I
2H
(Natural gas)
I
3P
(Propane)
Gas Connection
8.0mm compression fitting
8.0mm
compression
fitting
Heat Input
9.2 kW Gross
9.7 kW Gross
8.4 kW Net
8.8 kW Net
Dimensions
w 555mm. d 260mm. h 495mm.
Appliance Inlet Pressure
20 +/- 1 mbar.
37 mbar
Injector Size
2.3 mm
1.5 mm
Weight
20.9 Kg gross
NB: THIS APPLIANCE IS FITTED WITH A SPILLAGE MONITORING DEVICE, WHICH WILL
OPERATE IF THE FLUE IS NOT CLEARING THE COMBUSTION PRODUCTS. THE FIRE
WILL GO OUT IF THIS OCCURS. IF THE FIRE GOES OUT SEE SECTION 5
"COMMISSIONING THE APPLIANCE" IN THESE INSTRUCTIONS. WAIT THREE MINUTES
BEFORE RE-LIGHTING. IF THE FIRE REPEATEDLY GOES OUT, CHECK THE PILOT
BURNER AND THERMOCOUPLE FOR CORRECT OPERATION.
The spillage monitoring
shall not be put out of operation and shall not be adjusted by the installer.
When the spillage monitoring system, or any of its parts is exchanged only
the original manufacturers parts shall be used.
THIS DEVICE IS NOT A SUBSTITUTE FOR AN INDEPENDENTLY MOUNTED CARBON
MONOXIDE DETECTOR.