3.Function presentation
3 minutes protection
If the unit stops and you re start the unit or turn it on by the manual switch, the unit will not
start to run again for approx 3 minutes. This is a protection feature to safe guard the
compressor.
In low ambient conditions the heating output decreases.
Heating capacity
Working conditions
Defrosting
In the heating mode the unit will defrost automatically, maximizing the heating efficiency
(Lasting 2 - 10 minutes)
.
The fan motor will stop running whilst the unit is defrosting
.
Water pressure
protection
temperature or
8
4.1 Pipeline connection sketch
4. Installation
Y-shaped Filter
7
In order to use the unit correctly, please run the unit at environment temperature
0
~40
. The unit includes sophisticated electronic devices, prohibited to use water
from lake, untreated river water and groundwater!
Setup cannot affect the building structure and safety.
Notice:
A pressure realeasing
valve isto be fitted in
the installation.
Spec of Pressure
release valve:
Pressure: 0.7MPa
Notice:
Tempering valve required
Water Outlet
Water Inlet
Tap Water
Thermal expansion tank
(if required)
Magnesium
Condensate Outlet
Drainpipe
Barrel-drain
Pressure release valve
When the tank pressure reaches 0.7MPa, the Pressure release valve will open
automatically so as to decrease the pressure .
ATTENTION
Pipeline connection explanation
Installation of the water inlet or outlet pipes: The specification of the water inlet and
outlet thread is BSP3/4(internal thread).pipes must be heat-resistant and durable.
Installation of the pipe for Pressure release valve: The spec of the valve connecting
thread is BSP3/4(internal thread).After installation, it must be confirmed that the
drainpipe outlet is exposed in the air.
drainpipe is joined to the
pressure relief orifice of this valve, you must ensure that the flexble drainpipe
and exposed in the air.
When the flexible
is
pointing downwards
ATTENTION: The Pressure release valve attached with the unit must be installed,
will cause damage to the unit,
.
failure to do so
and possible personal injury
Do not use stainless steel fittings to connect directly with other metals to prevent
galvanic corrosion.
Drain the watertank through thedrain valve atthe bottom partof the unit.