31
7.Appendix
7.2 The method of grounding
7.3
of the
P&T valve
Use
Pressure release valve is used to pressure going too high inside the tank. When the pressure
reaches the set value, the valve will open automatically so as to decrease the pressure .
The handle of the safety valve should be pulled once every six months so as to remove the calcium
carbonate deposition decrease the temperature. Take care as the temperature of the discharging water
is very high.
Vent pipes should be thermally insulated to prevent the pipes freezing in the winter.
Remark:
P&T valve: actiontempreture: 99
℃
, action pressure:0.85MPa
WARNING
Fail to operatethe relief valveeasing gear atleast once everysix months mayresult in the
water heater exploding.Continuous leakage ofwaterfrom thevalve may indicates problem
with the waterheater.
32
7.Appendix
7.4 Drain out the water in the storage tank
loosen the screws and open the cover
Press the red button to reset
7.5
Use of the overheating protector
DANGER:
The operation of the thermal cut-out indicates a possibly dangerous situation.
Do not reset the thermal cut-out until the water heater has been serviced by a qualified
person.
The overhea
t
protector is used to turn the power off, preventing the water from being heated
too high. To return the unit to its normal operational status it will have to be reset manually.
Operation details
:
Cut out the water supply connection between the tap water supply and the tank by closing the
corresponding valve. Open the hot water outlet and then open the drain outlet valve at the same
time.
The water in the tank will be drained out through the drain outlet.