Troubleshooting
42
Figure 18: SS7 Master Alarm
Sample
The alarm messages are logged to an ―AccessAlarms.xxx‖ file until the file reaches
the default size of 512 kilobytes. Then, a new file is created with a higher numbered
extension. The default configuration allows up to 10 alarm files. When the directory
contains 10 files and a new log file is created, the oldest log file (the file with lowest
numbered extension) is automatically erased. A sample command to set the file size
to 1,024 kbytes and to set the number of files to 20 is shown below:
MML_TH> alarmd -n 20 -m 1024
The SS7 alarm groups and their associated alarm ID range are listed below:
TRMOD - translation module (820101 - 820104)
SPM - signaling point (SP) management (830101 - 830708)
UPM - user part management, such as MTP Level 3 (840101 - 840401)
SCCP - service connection control part management (850101 - 85150a)
MTPL1 - MTP Level 1 (860101 - 860136)
MTPL2 - MTP Level 2 (870101 - 870152)
ETMOD - Ethernet test module (880101 - 880501)
ISUP - ISUP management (890101 - 890133)
APM - Application Process Management (8b0101 - 8b030a)
OMAP - operation, maintenance, and administration part (8d0101 - 8d011f)
NIMOD - connection management (920101 - 920401)
TCAP - TCAP driver (950101 - 950806)
TCMOD - TCAP over TCP/IP connection management (960101 - 960206)
DKM - Distributed kernel memory (970101 - 970803)
ISUPMOD - ISUP management - distributed (990201 - 990407)
Timestamp
Alarm ID
Local signaling
point
Hostname
Alarm text
Alarm level