SS7 Quick Start Guide
23
Changes to the factory configuration are not required.
3.5.2 Viewing the Default SS7 Module Configuration
The SS7 module is factory configured using a set of Man Machine Language (MML)
commands entered at the Distributed7 MML prompt. This configuration includes
host names, spans, ports, and network parameters. The main default parameters are
listed below:
3.5.2.1 SS7 Module (Side A)
Parameter
Description
Hostname
solacomXX-1d (XX = shelf identifier)
Active span
Line 1 (clock source is obtained from the line)
Span configuration
T1 with ESF framing and B8ZS encoding
Maximum line length of 100 feet
Notify is enabled for framer line alarms
Network class type
Class B
Signaling ports
1 port (port 0 on Line 1)
Signaling port 0
64000 bits/s with idle detection
Table 2: SS7 Module Side A Default Parameters
3.5.2.2 SS7 Module (Side B)
Parameter
Description
Hostname
solacomXX-2d (XX = shelf identifier)
Active span
Line 1 (clock source is obtained from the line)
Span configuration
T1 with ESF framing and B8ZS encoding
Maximum line length of 100 feet
Notify is enabled for framer line alarms
Network class type
Class B
Signaling port (channel)
1 port (port 0 on Line 1)
Port 0 configuration
64000 bits/s with idle detection
Table 3: SS7 Module Side B Default Parameters
See Section 0 for information on changing the above configuration.
Содержание SS7
Страница 1: ...EdgeIQ R11 0 SS7 Quick Start Guide ...
Страница 4: ......
Страница 10: ......
Страница 12: ......
Страница 14: ......
Страница 64: ...Level 2 Tracing SS7 52 7 Load output 3 into Wireshark the following window appears ...
Страница 65: ......
Страница 66: ...B2214167 6 SR1 ...