SS7 Quick Start Guide
25
3.5.3 Changing the Default SS7 Module Configuration
Sample commands defining the default configuration for the
solacom25-1d
host are
shown below:
MML_TH> add-ss7board:hostname=solacom25-1d,boardnm=pmc8260,_
inst=0,ports=1, conf=OFF,clockmode=LINE,clockspan=1;
MML_TH> modify-ntwk:hostname=solacom25-1d,mode=DSTRBTD, _
NETMASK1=1fffff00, NETMASK2=1fffff00,DUALHOST=solacom25-1;
MML_TH> add-host:hostname=solacom25-1d,rmthost=solacom25-2d, _
ALIAS=solacom25-2, rmthosttyp=AMGR,conf=ON;
MML_TH> modify-port:hostname=solacom25-1d,boardnm=pmc8260_
,inst=0,portnum=0,baud=64000,LPBKMODE=NONE,IDLEDETECT=ON;
MML_TH> modify-line:hostname=solacom25-1d,boardnm=pmc8260,_
inst=0,span=1,line_typ=T1,line_frmmod=T1ESF,line_cod=T1B8ZS,_
line_len=L110,line_NTFY=ON;
Note:
An underscore at the end of a line means continue on the same line.
Highlighted parameters may require updates to suit your requirements.
To change the highlighted parameters…
1
Access the MML (see Section 3.5).
2
Update the parameter values.
For example, to change the port’s baud rate to 56000, the T1 framing mode to
T1ZBTSI, and the T1 line encoding to T1B7ZS, enter the following
commands:
MML_TH> modify-ss7board:hostname=solacom25-1d,_
boardnm=pmc8260,inst=0,ports=1,conf=OFF;
MML_TH> modify-port:hostname=solacom25-1d, baud=56000;
MML_TH> modify-line:hostname=solacom25-1d,_
boardnm=pmc8260,inst=0,span=1,line_typ=T1,_
line_frmmod=T1ZBTSI,line_cod=T1B7ZS,line_len=L110,_
line_NTFY=ON;
MML_TH> modify-ss7board:hostname=solacom25-
1d,boardnm=pmc8260,inst=0,ports=1,conf=ON;
MML commands are also described in the supplied
SS8 Distributed7 User Manual
.
Sample online help output for the
modify-port
command is shown below: