41
11. SPECIFICATIONS
Whole System Specifications
Range:
(Slope distance between instrument and measuring point)
(normal atmospheric conditions
*1
)
Standard Mode:
2
*2
to 100m
*3
Far Mode:
2
*2
to 250m
*4
/300m
*3
Operating time
*5
:
About 15 sec.
*1
/18 sec.
*6
Up to finishing distance measurement
(Rapid (single))
Operating range of function for automatically determining rotation direction:
Magnetic inclination is 80° or less and horizontal component is
more than 10µT
*7
Data collector:
SOKKIA total station/3-D station-compatible product
*7
Control panel (keyboard)
3 Keys
Indicator
5 LED
Audio tone
Yes
Operating temperature
-20 to 50°C
Storage temperature range
-30 to 70°C
Water resistance
IP55 (IEC 60529:2001)
Size
69 (L) X 80.5 (W) X 131 (H) mm (excluding antenna)
Weight
About 420 g (with BDC46C)
*
1
:
Normal: Slight haze, visibility about 20 km, sunny periods, weak scintillation.
*
2
:
Possible to use 1.8m (horizontal distance), height of instrument point and measurement point
is almost the same, instrument height is 1.5m, and prism height is 0.10m.
*
3
:
About 20m height difference between instrument and RC-Controller laser projection port.
*
4
:
About 40m height difference between instrument and RC-Controller laser projection port.
*
5
:
Time taken between the start of the search and the obtaining of distance measurement results
after the completion of Auto Pointing. Normal atmospheric conditions, instrument Turning
horizontally 90°, 100m distance between instrument and measuring point.
Depends on the conditions and wireless modem used.
*
6
:
At a distance of less than 5m, pole leaning slightly.
*
7
:
For details, contact your local dealer.
RC-Controller (RC-PR4)
Laser Projection Port
Signal source
Laser diode (IEC60825-1 Ed. 2.0: 2007/FDA CDRH 21 CFR Part
1040.10 and 1040.11 (Complies with FDA performance standards for
laser products except for deviations pursuant to Laser Notice No.50,
dated July 26, 2001.))
Wavelength: 785nm
Beam projection area
Horizontal direction:
-10 to 10°
Angle of elevation:
More than 40°
Angle of depression:
More than 30°
Rotation direction detector
Direction detector
magnetic compass sensor (geomagnetic measurement method)
With automatic/manual calibration function
Measurement resolution
±1°