59
12. SETTING INSTRUMENT STATION
6.
Input coordinates for the first
known point and press [NEXT] to
move to the second point.
• When [LOAD] is pressed,
registered coordinates can be
recalled and used.
Station Data and Azimuth
Angle PROCEDURE Reading
in Registered Coordinate
Data"
• Press {ESC} to return to the
previous known point.
7.
Repeat procedures 4 to 6 in the
same way from the second point.
When the minimum quantity of
observation data required for the
calculation is present, [CALC] is
displayed.
8.
Press [CALC] to automatically
start calculations after
observations of all known points
are completed.
Instrument station coordinate and
standard deviation, which
describes the measurement
accuracy, are displayed.
9.
Press [RESULT] to check the
result.
• Pressing {ESC} returns to the
previous screen.
• Press [ADD] when there is a
known point that has not been
measured or when a new known
point is added.
20.000
1st PT
30.000
40.000
10.000m
HR
REC
LOAD
NEXT
20.000
3rd PT
30.000
40.000
10.000m
HR
REC
NEXT
LOAD
CALC
1 s t
2 n d
3 r d
- 0 . 0 0 1 0 . 0 0 1
- 0 . 0 0 1 0 . 0 0 1
0 . 0 0 5 0 . 0 1 0
4 t h - 0 . 0 0 3 - 0 . 0 0 2
*
RE_CALC
OMIT
RE_MEAS
ADD
9 . 9 9 9
4
RESULT
OK