17. OFFSET MEASUREMENT
78
2. Sight the offset point and press
[DIST]
in the first page of the
Meas mode screen to begin
measurement.
The measurement results are
displayed. Press
[STOP]
to stop
the measurement.
3. Press
[OFFSET]
in page three of
Meas mode to display <Offset>.
4. Enter the instrument station data.
C
“12.1 Entering Instrument
Station Data, PROCEDURE
Reading in Registered
Coordinate Data”.
5. Select “Offset/Dist” and press
[EDIT]
.
Input the following items.
(1) Horizontal distance from the
target point to the offset point.
(2) Direction of the offset point.
• Direction of offset point
• Press
[OBS]
to re-observe the
offset point.
6. Press
[OK]
on the screen of step
5 to calculate and display the
distance and angle of the target
point.
←
: On the left of the target point.
→
: On the right of the target
point.
↓
: Closer than the target point.
↑
: Beyond the target point.
EDIT
OK