
13. RESECTION MEASUREMENT
54
8. If there are problems with the
results of a point, align the cursor
with that point and press
[BAD]
.
“*” is displayed on the left of the
point. Repeat for all results that
include problems.
9. Press
[RE CALC]
to perform
calculation again without the point
designated in step 8. The result is
displayed.
If there are no problems with the
result, go to step 10.
If problems with the result occur
again, perform the resection
measurement from step 3.
• Press
[RE OBS]
to measure the
point designated in step 9.
If no points are designated in
step 9, all the points or only the
final point can be observed
again.
10. Press
[OK]
in the screen of step 6
to finish resection measurement.
The instrument station coordinate
is set.
Press
[YES]
when you want to set
the azimuth angle of the first
known point as the backsight
point.
• Press
[NO]
to return to Meas
Mode without setting the azimuth angle.
$
• It is also possible to perform resection measurement when
[RESEC]
on Meas
mode screen.
C
Allocating [RESEC]: "24.2 Allocating Key Functions"
• Even if “inch” is selected in Config mode, standard deviation is displayed in
“feet.”
30R.book 54
ページ
2003年12月16日 火曜日 午後5時15分
Содержание 30R Series
Страница 8: ...vi 30R book vi ページ 2003年12月16日 火曜日 午後5時15分 ...
Страница 172: ...29 REGULATIONS 164 CE Conformity Declaration 30R_29 FM 164 ページ 2003年12月18日 木曜日 午後5時11分 ...
Страница 173: ...165 29 REGULATIONS 30R_29 FM 165 ページ 2003年12月18日 木曜日 午後5時11分 ...
Страница 177: ...30R book 1 ページ 2003年12月16日 火曜日 午後5時15分 ...
Страница 178: ...8th ed 13 0408 Printed in Japan 2002 SOKKIA CO LTD 30R_C3C4 FM 2 ページ 2004年8月23日 月曜日 午後5時43分 ...