Remove overpressure valve from the cartridge.
Turn overpressure valve to the left as far as the limit stop
(see photo) and remove upwards.
Insert SOG hose connection into the bayonet and turn
right until you feel the hose connection click into place.
It this appears difficult, ease in O-ring with silicone spray
or some soap.
Insert the hose in the cover connection of the cassette. Use the spiral hose supplied from the cassette to the filter.
However, this should not exceed a length of 60 cm. For further routing we recommend the black wastewater pipe- available in camping re-
tailers - or a 5/8” sanitation
Make sure during assembly that the hose and pipe are routed so that no siphon forms, otherwise condensation would collect here and
block the pipe over time.
If stiffness occurs after some time when disconnecting the house coupling, please spray these plastic parts with silicone spray – likewise the
plugs.
This results in reduced wear, while retaining the smooth sliding property at the same time.
hose Cassette fan that is gastight.
The hose must be disconnected from the cassette upwards at the green hose connector and sealed with the enclosed plugs during empty-
ing!
15/16
Open the blade valve and hold a burning incense (joss) stick or cigarette above it. If the smoke is drawn down into the holding tank the
ventilation system is working correctly.
Functional test of the ventilation system - Mandatory
Adapting the waste air hose:
-4-
13
14
15
16
17
GB