blank side
black side
-2-
If there is already a hole for the control magnet in the
slide handle, the magnet will be inserted here.
First push the control magnet with the face marked black
into he hole so that it closes flat with the outer side of the
slide handle.
If there is not a hole in the slide handle on the ventilating
knob side of the cartridge, this must be provided subse-
quently.
Follow the dimensions according to the photo.
Unlock slide handle and pull on, locate cartridge in reverse
position and unscrew the four Torx screws with Torx in-
sert TX 10. Remove slide handle.
Clamp slide handle in machine vise (see photo).
Pre-drill hole with 3 mm drill and then fully drill with 6 mm
drill.
Attention: drill both holes at high speed and low rate of
feed.
First push control magnet with the face marked black into
the hole(direction of the arrow) until this closes with the
outer side of the slide handle(black side).
Fasten the control magnet with silicone.
Insert slide handle into the guide rails again and screw in.
1
6
5
4
24 mm
15 mm
6 mm ø
3
2
GB