Lay cable harness and fasten with the adhesive base (1).
Connect brown cable of the cable harness to the red
quick connector (2) on the brown cable of the existing ca-
ble harness.
Lay cable harness further upwards to the solenoid valve
(3)(photo 12).
At the new versions of Dometic CT 3000 is the se-
noid valve placed in the toilet service space at the
left hand side. In that Case, is the ground cable
(earth cable)
and not white!
blue
Pull out white or blue cable on solenoid valve (3) and in-
sert black cable with dual connector of the cable harness.
Place white or blue cable on the free slot again (4). Lay the
end of the cable harness to the filter cartridge and con-
nect to same color of the ventilator.
-3-
7
8
9
10
Toilets made after 07/2008 have supports 1 for the
reed sensor as well as cable supports (2).
Pull off adhesive film. Insert sensor holder in screw pin and
press upwards, then screw in with screw 3.9 x 6.5
(tighten screw hand-tight).
Sensor must be located on the toilet housing (3).
If the toilet does not have a support for the reed sensor,
the sensor holder should be attached in the service com-
partment on the left exactly as shown in photo (8), this be-
ing fully sufficient.
Remove adhesive surfaces and clean of grease, pull off ad-
hesive film. Ad here sensor holder with faces located on
the housing.
Sensor must be located on the toilet housing (3).
Preassemble the reed sensor before installing the cable
harness - see photo 7-8-9.
Push reed sensor through the cable opening and clip the
reed sensor into the mounted sensor holder.
1
12
4
3
3
2
3
11
2
1