SOFAR 3K~6KTLM-G2
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 49 -
Enable or disable the power derate function of the inverter, and set the
derate ratio.
17. Set Reflux
Enable or disable the anti-reflux function of the inverter, and set the reflux
power. This function needs to be used with external CT, please refer to this
manual 4.5 RS485, CT, inverter logic interface connection for details.
“Enter”
→
1Enter setting
“OK”
→
1 Set Time
2 Event List
2Clean Energy
“Up”
↑
3 System Info
“Up”
↑
3 Clean Events
“Down”
↑
4 System time
“Down”
↑
......
5Software Update
17 Set Reflux P
“OK”
→
Input password!
“OK”
→
****
Input 0001
0001
“OK”
→
Reflux Enable
“OK”
→
*.**KW
Input the allowable export power
Press
“
Up
”
or
“
Down
”
to change the value of the first digit. Press
“
OK
”
to switch to second digit.
Press
“
Up
”
or
“
Down
”
to change the value of the second digit. After inputting all digit press
“
OK
”
to confirm.
18. MPPT Scan
Shadow scanning, when the component is blocked or abnormal, causing
multiple power peaks, by enabling this function, the peak point of maximum
power can be tracked.
19. Start Time
Startup time and recovery reconnection time can be set.
20.
Set ElecMeter
Enable or disable meter functions.
21. Logic interface
Enable or disable logical interfaces. Please refer to this manual 4.5 RS485,
CT, inverter logic interface connection for details.
22. Set Power Ratio