Step 2
Disassemble the AC connector according to the figure shown below: insert the
AC output cable (with its insulation layer stripped according to step 1) through the
waterproof locking cable gland.
Step 3
Connect AC output cable as per the following requirements:
Connect the yellow-green wire to the hole labeled "PE", fasten the wire using an Cross
screwdriver;
Connect the brown wire to the hole labeled "L", fasten the wire using an Cross
screwdriver;
Connect the blue wire to the hole labeled "N", fasten the wire using an Cross screwdriver.
Step 4
Insert the AC connector and hear "click", then tighten the waterproof nut at the
instantaneous value, as shown in the figure below, to ensure that the cable is firmly
connected.
Figure 4-11
①
②
L--Brown, N--Blue, PE--Yellow-green