stripper, as shown in Figure 4-1.
Figure4-1 Preparing a ground cable (1)
Note
:
L2 is 2 to 3mm longer than L1
Step 2
Insert the exposed core wires into the OT terminal and crimp them
by using a crimping tool, as shown in Figure 4-2.
Figure4-2 Preparing a ground cable (2)
Note 1:
L3 is the length between the insulation layer of the ground cable and the
crimped part.L4 is the distance between the crimped part and core wires protruding from
the crimped part.
Note 2:
The cavity formed after crimping the conductor crimp strip shall wrap the
core wires completely. The core wires shall contact the terminal closely.
Step 3
Install the crimped OT terminal, flat washer using M6 screw, and
tighten the screw to a torque of 6 N.m using an Allen wrench.
Figure4-3 Ground terminal
composition
1.Tapped hole
2.OT Terminal