©2009 NETCONS, s.r.o.
Page 16 of 27
An alarm can generate alert by calling of or sending SMS to up to three
predefined phone numbers or in case of alarm invoked by change of inputs,
possible alert actions include control of Main switched output and supporting
simple scripting allowing IQSD-GSM to act as user-programmable, event-
driven controller.
3.10.1
Defining phone numbers for SMS and ringing up alerts
Phone numbers must be entered in international format, see following table.
SMS Command
Description
SMS Response
Type
ALAR
421265440655
Add a new number into list for alarm
alerts using SMS message and call
back.
ALAR4212654
40655
- OK
Cfg
ALARMNUMBER-
421265440655
Remove a number from list for
alarm alerts using SMS message
and call back.
ALARMNUMBER-4212654
40655
- OK
Cfg
ALARMNUMBER-ALL
Remove all numbers from list for
alarm alerts using SMS message
and call back.
ALARMNUMBER-ALL- OK
Cfg
ALARMNUMBER=LIST Get list of phone numbers for alarm
alerts using SMS message and call
back.
LIST 421265440655
Cfg
When generating alerts, numbers in list are processed per their order – first
number as first, the last number as last.
3.10.2
Battery charge alarm
Monitoring remaining charge of IQSD-GSM‟ internal backup battery when AC
mains power is temporary failed is easily possible thanks to
BATALARM
command.
You can define up to three battery charge thresholds, given in % of remaining
charge. Threshold value can be from 30 to 95 %. Device is automatically
switched off once remaining charge falls below 20%.
SMS Command
Description
SMS Response
Type
BATALARM=30,60,90 Send alert SMS every time when
remaining battery charge falls below
defined thresholds 30,60 and 90%.
BATALARM=30,60,90
, OK
Cfg
BATALARM=00,00,50 Send alert SMS every time when
remaining battery charge falls below
defined threshold 50%.
BATALARM=00,00,50, OK Cfg
BATALARM=00,00,00 Disable sending remaining battery
charge alerts
BATALARM=00,00,00, OK Cfg
BATALARM?
Get configuration of BATALARM
BATALARM=00,00,00
Cfg