INF, to send 

STATUS

 message by SMS to number preconfigured by the 

ALARMNUMBER

 command (e.g. 

ALAR421903123456

, see 

chapter Alarms) 

 
Example of SCHEDULER? command output (four actions were recorded): 

o

 

11:00,*,ON  Turn on Main switched output every day at 11:00 

o

 

14:30,*,OFF  Turn off Main switched output every day at 14:30 

o

 

01:30,1,RES  Restart Main switched output every Monday at 01:30 

o

 

19:00,5,INF  Send Status SMS every Friday at 19:00 

 

3.9

 

Counters 

 

Six independent counters increments their status upon change on IQSD-GSM 
inputs and outputs. 

 
 

SMS Command 

Description 

SMS Response 

Type 

COUNTER1? 

Get status of Counter1, increments 
on change of Digital Input1 

COUNTER1=0

 

Ctrl

 

COUNTER2? 

Get status of Counter2, increments 
on change of Digital Input2 

COUNTER2=0

 

Ctrl

 

COUNTER3? 

Get status of Counter3, increments 
on change of Main switched output 

COUNTER3=0

 

Ctrl

 

COUNTER4? 

Get status of Counter4, increments 
on change of Aux switched output

 

COUNTER4=0

 

Ctrl

 

COUNTER5?

 

Get status of Counter5, increments 
on pressing of Push Button 

COUNTER5=0

 

Ctrl

 

COUNTER6? 

Get status of Counter6, increments 
on loosing registration into GSM 
network 

COUNTER6=0

 

Ctrl

 

COUNTERX? 

Get status of all counters 

COUNTER=0,0,0,0,0,0

 

Ctrl

 

CLEARCOUNTER1 

Clear status of counter 1 (2-6) 

CLEARCOUNTER1- OK

 

Ctrl 

CLEARCOUNTERALL  Clear status of all counters 

CLEARCOUNTERALL- OK

 

Ctrl 

 
Counter1 is incremented by 1 after commands 

RESTART

TURNOFF

TURNON

 

Highest possible status of a counter is 65535. 
 

3.10

 

Alarms 

 
IQSD-GSM supports three independent alarms. 

 

 

Alarm invoked by change on inputs, having highest priority 

 

AC mains power failure alarm 

 

Backup battery remaining charge alarm, having lowest priority 

 

Содержание IQsocket DIN/IQSD-GSM

Страница 1: ...User guide www IQsocket eu Intelligent power sockets IQsockettm DIN IQSD GSM makes your life more comfortable User Guide IQSD GSM documentation v1 1 1 R5...

Страница 2: ...7 Response messages settings 13 3 8 Scheduler feature 14 3 9 Counters 15 3 10 Alarms 15 3 10 1 Defining phone numbers for SMS and ringing up alerts 16 3 10 2 Battery charge alarm 16 3 10 3 AC mains p...

Страница 3: ...or medical applications Product must be mounted on DIN rail 35mm EN50022 inside a suitable enclosure providing environmental protection The product contains no serviceable parts or internal adjustment...

Страница 4: ...DIN rail mounting IQsocket IQSD GSM helps to control any electric appliance remotely over GSM network IQSD GSM is managed by SMS messages or phone call It can work also as a programmable regulator wit...

Страница 5: ...ter not included in product package o External detector of opened door window shake detector not included in product package o Any other external detector with contact output can be connected Alarm de...

Страница 6: ...of 27 2 Installation Before starting installation please read this manual and take into account Important information section at beginning of this manual 2 1 Wiring the IQSD GSM Wire connections per f...

Страница 7: ...g SIM PIN usage using appropriate command usually located in Settings phone menu Now you can remove the SIM card from phone and insert it into your IQSD GSM Insert SIM card with inactive PIN code auth...

Страница 8: ...AND e g 3366STATUS o With pre configured security password by command SMSPIN 3366 COMMAND e g STATUS o with un configured security password SMSPIN There are two kinds of commands Control commands labe...

Страница 9: ...STARTTIME Restarted Ctrl STATUS Get status of IQSD GSM Outputs Temperature digital and voltage inputs AC mains Backup Battery charge time and GSM signal Output OFF OFF Temperature 22 5 C NA Input OFF...

Страница 10: ...ESTART Change negate status of Main switched output for time preconfigured by command RESTARTTIME call is rejected RING RESTART OK Cfg RING SWITCH Change negate status of Main switched output call is...

Страница 11: ...t current settings of Date time DATE yy mm dd hh mm ss zz OK Cfg 3 5 Manual Control IQSD GSM can be controlled manually using push button located in the bottom left corner of front panel see drawing i...

Страница 12: ...inserted SIM card IQSD GSM allows to define up to 20 permitted phone numbers each containing up to 15 numerals In case of using SMSPIN right before each SMS command is placed PIN code without any spac...

Страница 13: ...od and executed successfully For this purpose we implemented response messages confirming each command or informing you when an error is detected In case of SMS commands you will be notified by back S...

Страница 14: ...ION at time hh mm every day of week DOW SCHEDULER hh mm DOW ACTION OK Ctrl SCHEDULER hh mm Remove scheduler record for particular time hh mm SCHEDULER hh mm OK Ctrl SCHEDULER Get list of all scheduler...

Страница 15: ...crements on change of Digital Input2 COUNTER2 0 Ctrl COUNTER3 Get status of Counter3 increments on change of Main switched output COUNTER3 0 Ctrl COUNTER4 Get status of Counter4 increments on change o...

Страница 16: ...NUMBER ALL OK Cfg ALARMNUMBER LIST Get list of phone numbers for alarm alerts using SMS message and call back LIST 421265440655 Cfg When generating alerts numbers in list are processed per their order...

Страница 17: ...in parentheses POWERFAULT NO INFO Cfg When AC mains fails for time longer than 10 seconds device will send following SMS alert message to the numbers set by ALARM command Power failed In case power is...

Страница 18: ...language user must know at least basic knowledge of algorithmization Program is defined in form of row there can be up to 6 such rows A program row can be inserted using ID command and removed using...

Страница 19: ...nored like if it is always true E_VoltageIn means evaluation condition for VoltagIn input having syntax beginning with condition symbol or followed by the value in Volts itself Some examples 5 conditi...

Страница 20: ...l program rows ID0 OK Ctrl Once program rows were entered into IQSD GSM use command PROGRAM to start its execution SMS Command Description SMS Response Type PROGRAM START Start execution of the progra...

Страница 21: ...nding following SMS command ALARM 421903123456 Then enter following two program rows ID1 0 1 S 1 Closed ID2 1 0 S 0 Open And then let s start the program issuing SMS command PROGRAM START When needed...

Страница 22: ...en there is Log 0 level at both inputs turn off the Main switched output Enter following two program rows ID1 0 1 1 TURNON ID2 0 1 1 TURNON ID3 1 0 0 0 TURNOFF And then let s start the program issuing...

Страница 23: ...n case of permitted phone numbers list is active but used number is not included in it Timeout 10 minutes interval since power on or since last configuration command has timed out In order to continue...

Страница 24: ...e per second indicates SIM card with active PIN authorization It is necessary to disable the PIN authorization using a GSM phone RELAY yellow blinking fast indicated a HW failure 5 Factory default set...

Страница 25: ...isolated max 30V input detection threshold 1V 1x Analog voltage sensing 0 30VDC 0 24VAC Resolution 1V 2x Temperature sensor inputs 1 Wire for Dallas DS18B20 sensor Voltage outputs 5VDC 100mA protected...

Страница 26: ...roduct is not intended as security device alarm functions are just auxiliary Product can be operated only indoor office house environment Do not expose it to humid wet nor chemically aggressive enviro...

Страница 27: ...ct family uses following ordering code system IQSx y z Example IQSD GSM Product family W WALL R RACK D DIN Product model GSM IP RS232 HDO IPGSM Output Socket type F Schuko E French Optional accessorie...

Отзывы: