©2009 NETCONS, s.r.o.
Page 25 of 27
Parameter
Default setting
RING
NOACTION
RESTARTTIME
10
RINGONTIME
30
SMSPIN
NOPIN
SECNUMBER
NO
SMSCONFIRM
YES
RINGCONFIRM
NO
ERRORREPLY
YES
BATALARM
00,00,00
POWERFAULT
NO
PROGRAM
STOP
OUTPUT
REMEMBER
6
Technical specification
Model
IQsocket IQSD-GSM
Mains power
230VAC / 50Hz, 15mA
Backup battery
4.2V Li-Ion
Switched Outputs
MAIN 230V, 10A max (resistance load)
AUX 230V 100mA (resistance load)
Inputs
2x Digital, optic-isolated, max. 30V input, detection threshold 1V
1x Analog voltage sensing 0-30VDC/0-24VAC. Resolution 1V
2x Temperature sensor inputs, 1-Wire, for Dallas DS18B20 sensor
Voltage outputs
5VDC/100mA, protected by auto-resettable fuse
12VDC/80mA, non-protected!
4.2VDC/1A, non-protected!
Management
Via SMS messages
Security
PIN code protected commands
Permitted phone numbers list
Detectors
Inbuilt thermometer
Alarm input for external detectors (motion, gas, water, fire,
door/Windows, and more.)
GSM
EGSM900, GSM850 Class4 (2W)
DCS1800, PCS1900 Class1 (1W)
SIM card Plug-in 3V
External 2dBi antenna via SMA connector
Indicators
POWER: red LED
GSM: green LED
RELAY: yellow LED