background image

    

 

21. Hazard lights Output (default=normal) 
When set as Normal: 
Connect the hazard lights output as normal using the Y-splitter lead. 
 
If the Normal connection does not work then connect the hazard lights output to the hazard switch as shown below and set feature 
#21 as Pulse or Continuous depending on the type of hazard switch 

O

I

Control Unit

Sniper

X2

Hazard 

Switch

Hazard Lights 

Output

Hazard

Lights

 

 

When selecting Pulse or Continuous, try the factory default first (0.5sec). If the hazard lights do not flash as expected proceed to the 
hazard light learning as follows:     

Turn the ignition on and off 3 times (on-off-on-off-on-off). 

The siren will chirp once to confirm the system is in learning mode. 

Turn the vehicles hazard lights on and the hazard lights start to flash. 

Within 10 sec. press and hold the valet switch. 

The LED will turn on to confirm the valet switch is pressed. 

Release the valet switch once the hazard lights have flashed 10 times. 

The LED will turn off and siren will chirp once to confirm the learning is complete.   

 

 

The system will leave the learning mode automatically if the valet switch is not pressed within 10 sec. or if the ignition is turned on. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SNIPER X2

Страница 1: ...d to the system in the factory Follow the procedure below to program a new remote control to the system Turn the ignition on with the system disarmed Within 10 seconds press valet switch 6 times The s...

Страница 2: ...button 1 has not been pressed within 10 sec 1 8 Optional Programmable Features No Chirp Function 1 Chirp 2 Chirp 3 Chirp 4 Chirp 1 1 chirp Chirp Confirmation On Off 2 2 chirp Door Lock with Passive A...

Страница 3: ...ed after turning the ignition off 05 Door Lock Time default 0 8 When set as 0 8 sec The system will send a 0 8 sec pulse when locking the doors When set as 3 6 sec The system will send a 3 6 sec pulse...

Страница 4: ...ing the ignition off and opening and then closing the door the engine disable relay will activate within 10 seconds but the system will still be disarmed The 10 sec countdown will be interrupted immed...

Страница 5: ...h the system disarmed and the ignition on Press button 1 for 2 sec to activate the anti hijacking and the hazard lights flash once to confirm The anti hijacking countdown will start depending on the s...

Страница 6: ...azard lights do not flash as expected proceed to the hazard light learning as follows Turn the ignition on and off 3 times on off on off on off The siren will chirp once to confirm the system is in le...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Отзывы: