background image

    

 

 
07. Door Unlock with Disarming (default=driver) 
When set as Driver: 
Only the drivers door will be unlocked when pressing button #2 to disarm the system.    Pressing button #2 again within 3 seconds will 
unlock the rest of the doors. 
 
When set as All: 
All the doors will be unlocked when pressing button #2 to disarm the system. 
08. Siren/Horn Output (default=siren) 
When set as Siren: 
Select the Siren option when connecting an external siren. 
 
When set as Horn: 
Select the Horn option when connecting the output to the cars horn. Note a relay 

must

 be used.     

 
09. Alarm Condition Cycle Duration (default=30 sec.) 
When set as 30 sec. or 60 sec.: 
The siren will sound for 30 sec. (or 60 sec) when the system is triggered and released.    The siren will sound for 30 sec. (or 60sec) 
x 3 cycles if the system is triggered continuously. 
 
10. Interior Light Delay (default=disable=5 sec.) 
When set as Disable (=5 sec.): 
The siren chirps 3 times and the hazard lights flash 3 times immediately if any of the doors, boot or bonnet are not closed properly 
when remote arming the system. The relevant input will be bypassed until the door/boot/bonnet is closed. 
 
When set as 25-40-60 sec.: 
The siren chirps 3 times and hazard lights flash 3 times immediately when remote arming the system if the boot or bonnet are not 
closed properly.    The boot & bonnet will be bypassed until both are closed properly. 
The siren chirps 3 times and hazard lights flash 3 times in 25sec.(or 40, 60sec.) after remote arming the system if the doors are not all 
closed properly. The doors will be bypassed until they are all closed properly. 

 

11. Auto. Rearming (default=disable) 
When set as Enable: The system will arm itself again automatically 30 seconds after disarming the system if no doors are opened. 
Opening a door after disarming the system will deactivate the auto rearming feature. 
 
12. AED, Auto Engine Disable (default=disable) 
When as Enable: After parking the car, turning the ignition off and opening and then closing the door the engine disable relay will 
activate within 10 seconds but the system will still be disarmed. 

-  The 10 sec. countdown will be interrupted immediately when opening a door, the countdown will restart when the door is closed.
-  Pressing the remote to arm the system during the 10 sec. countdown will activate the AED immediately. 
-  To deactivate the AED: 

a) With the system disarmed, remote arming the system then disarming will deactivate the AED at the same time. 
b) With the system armed, remote disarming the system will deactivate the AED at the same time. 
c) By override (when the system is disarmed). 

*  The AED will not active under valet mode.    To disable the AED you must leave the valet mode. 
*  When the AED is activated, the system cannot enter the following modes: 

a) Code Learning 
b) Programming Mode 
c) Hazard lights Calibration Mode 
d) Anti-hijacking 

 
13. Door Open Alerts (default=disable) 
When set as Mode 1: 

-  The hazard lights will flash when a door is opened with the ignition on until the door is closed or the ignition is turned off. 
*  The feature will not be activated if the door is opened whilst the ignition is on. 

 

 

When set as Mode 2: 

-  The hazard lights will flash when a door is opened regardless of whether the ignition is on of off and until the door is closed. 
*  The feature will be activated regardless of whether the ignition is turned on or off. 

 
14. Total/Comfort Closure (default=disable) 
The CH3 wire is designed for the option of automatically closing the windows when arming the system. This feature requires that 
the vehicle has Total/Comfort Closure. 
When set as Disable:   
The CH3 output will not be activated when arming the system but can be controlled as follows: 

With system armed or disarmed. 

Press and hold button #1+3. 

After 1 sec. the CH3 output will be activated until button #1 is released. 

 
When set as 15, 30 or 40 sec.: 
When arming the system the CH3 will send a 15 sec.(or 30, 40) pulse to close the windows automatically.    Pressing the remote to 
disarm the system during the 15 sec.(or 30, 40) will deactivate the CH3 output immediately. 

Содержание SNIPER X2

Страница 1: ...d to the system in the factory Follow the procedure below to program a new remote control to the system Turn the ignition on with the system disarmed Within 10 seconds press valet switch 6 times The s...

Страница 2: ...button 1 has not been pressed within 10 sec 1 8 Optional Programmable Features No Chirp Function 1 Chirp 2 Chirp 3 Chirp 4 Chirp 1 1 chirp Chirp Confirmation On Off 2 2 chirp Door Lock with Passive A...

Страница 3: ...ed after turning the ignition off 05 Door Lock Time default 0 8 When set as 0 8 sec The system will send a 0 8 sec pulse when locking the doors When set as 3 6 sec The system will send a 3 6 sec pulse...

Страница 4: ...ing the ignition off and opening and then closing the door the engine disable relay will activate within 10 seconds but the system will still be disarmed The 10 sec countdown will be interrupted immed...

Страница 5: ...h the system disarmed and the ignition on Press button 1 for 2 sec to activate the anti hijacking and the hazard lights flash once to confirm The anti hijacking countdown will start depending on the s...

Страница 6: ...azard lights do not flash as expected proceed to the hazard light learning as follows Turn the ignition on and off 3 times on off on off on off The siren will chirp once to confirm the system is in le...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Отзывы: