background image

    

 

 

 

SNIPER X2 VEHICLE SECURITY SYSTEM 

 

Installation Manual 

 

 
1. INSTALLATION 
1.1. Arm Condition Memory 
If power to the alarm is removed it will remain in the same status when power it restored. 
 
1.2. Immobiliser Relay Wiring 
The system offers two ways of wiring the immobiliser as shown below.   
When wired for Normally Open the immobiliser relay is switched on when the alarm is disarmed (fail secure). When wired as Normally 
Closed the relay is on when the alarm is armed (fail safe).   
 

Wiring Diagram - Immobiliser Relay NO & NC

Normally Closed Immobiliser Connection (Fail Safe)

87a - Normally Closed

87 - Normally Open

Off

Acc

On

Start

86

85

87

87a

30

To +12V DC or Acc.

W2-8

fig. 2

Normally Open Immobiliser Connection (Fail Secure)

87a - Normally Closed

87 - Normally Open

Off

Acc

On

Start

86

85

87

87a

30

To Acc.

W2-7

fig. 1

 

1.3. Programming New Remote Controls 
The included remote controls have been programmed to the system in the factory.    Follow the procedure below to program a new 
remote control to the system: 

Turn the ignition on with the system disarmed. 

Within 10 seconds, press valet switch 6 times. 

The siren sounds for 2 sec. to confirm the system is now in code learning mode. 

Within 10 sec., press any button of 1

st

 remote control 

 

The siren will sound for 1 sec. and hazard lights flash twice to confirm the 1

st

 remote has been programmed to the system and all 

the previous codes in the system will be erased entirely. 

Within 10 sec., repeat for the 2

nd

 remote control and again for 3

rd

 and 4

th

 remotes as applicable. 

Up to 4 remotes can be programmed to the system 

The system will leave the code learning mode after programming 4 remotes to the system and the siren will sound for 2 
seconds

 

to confirm. 

If no buttons are pressed within 10 seconds, the system will leave the learning code mode and the siren will sound for 2 seconds 
to confirm. 

The system will leave the code learning mode if the ignition is turned off at any time and the siren will sound for 2 seconds to 
confirm. 

 
 

 

Содержание SNIPER X2

Страница 1: ...d to the system in the factory Follow the procedure below to program a new remote control to the system Turn the ignition on with the system disarmed Within 10 seconds press valet switch 6 times The s...

Страница 2: ...button 1 has not been pressed within 10 sec 1 8 Optional Programmable Features No Chirp Function 1 Chirp 2 Chirp 3 Chirp 4 Chirp 1 1 chirp Chirp Confirmation On Off 2 2 chirp Door Lock with Passive A...

Страница 3: ...ed after turning the ignition off 05 Door Lock Time default 0 8 When set as 0 8 sec The system will send a 0 8 sec pulse when locking the doors When set as 3 6 sec The system will send a 3 6 sec pulse...

Страница 4: ...ing the ignition off and opening and then closing the door the engine disable relay will activate within 10 seconds but the system will still be disarmed The 10 sec countdown will be interrupted immed...

Страница 5: ...h the system disarmed and the ignition on Press button 1 for 2 sec to activate the anti hijacking and the hazard lights flash once to confirm The anti hijacking countdown will start depending on the s...

Страница 6: ...azard lights do not flash as expected proceed to the hazard light learning as follows Turn the ignition on and off 3 times on off on off on off The siren will chirp once to confirm the system is in le...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Отзывы: