System-Setup Screen 

The 

Setup 

screen displays basic information about the unit. Use the functions on the screen to 

restart the unit, return all settings to their factory defaults, and to change the names of the inputs. 

 

 

Product: 

The top left part of the screen shows the various versions, options, identifiers, etc., 

associated with the product’s hardware, firmware and software and also provides a means of 
setting controls to defaults or restarting the unit.  Note that the Firmware release is in two parts, the 
left-hand being for the Administration module FPGA and the right-hand part being for the I/O 
module FPGA. 

 

To restart the unit, simulating a power-up/power-down cycle, click 

Restart

To reset all of the unit’s settings to their factory defaults, click 

Factory Defaults

 

NOTE: this also clears all of the saved memory settings.

 

To reset all of the unit’s settings to their factory defaults, leaving user memories intact, click 

Default Settings

 

SFP Details: 

The top right part of the screen shows the details of the SFP transmitters and 

receivers fitted.  The Status column indicates whether the SFPs fitted are correct for the particular 
product. The difference between the TX80, 81, 82, 83, 84 products is purely the wavelengths of the 
transmitters fitted.  

NOTE

: SFP details are read only at start up so the unit must be restarted if an 

SFP is changed. 

 

Input 1-8 Name: 

The bottom half of the screen has entry fields for 8 

Input Names

. These are the 

input names displayed in logging. To change a name, type the name in the text field and click 

S

To return the name to its factory default, click 

P

.   

Issue 1 Rev 2 

 

© 2012 Snell Limited 

Page 10

Содержание IQOTX80

Страница 1: ...User Manual IQOTX80 IQOTX81 IQOTX82 IQOTX83 IQOTX84 IQOTX99 3G HD SD SDI Multi Channel Fiber Transmitter snellgroup com...

Страница 2: ...6 Screen 16 Logging 17 RollCall Log Fields 22 System RollTrack Screen 24 To configure a RollTrack action 25 Viewing RollTrack Information 25 This information applies to the transmitter modules in the...

Страница 3: ...n of the product with a partial fit of channels or with non standard combinations of wavelengths Block Diagram Rear Panel View Single width Fibre and DIN1 0 2 3 IQOTX8_78 1A3 Single width Fibre and HD...

Страница 4: ...1470 1610nm CWDM optical transmitters IQOTX8379 1A3 As IQOTX8079 1A3 but fitted with 1470 1610nm CWDM optical transmitters IQOTX8380 2A3 As IQOTX8080 2A3 but fitted with 1470 1610nm CWDM optical trans...

Страница 5: ...t LC single mode SFP Conforms to SMPTE 297 2006 Outputs 1 to 4 per Channel Controls Indicators Power OK Green CPU OK Green flashing Good Hardware OK Green Warning SFP fit not as sold Yellow SFP warnin...

Страница 6: ...15 dB 270 Mbps 1 5 Gbps 10 dB 3 Gbps Output jitter SD SDI 0 2 UI 10 Hz 0 2 UI 1 kHz 3G HD SDI 1 0 UI 10 Hz 0 2UI 100 kHz Module power 10 5 W max Depends on SFP fitted 1310 nm Tx Wavelength 1310 nm Sp...

Страница 7: ...BNC 75ohm panel jack connectors 8 8 6 4 2 FIBER OUT 2 7 5 3 1 FIBER OUT 1 1 SERIAL IN 2 IQOTX8_ 80 2A3 7 2 4 3 SERIAL IN 1 5 6 Fiber Outputs IQOTX8_78 1A3 and IQOTX8_79 1A3 Fiber outputs from the unit...

Страница 8: ...present Red flashing Input detected but rate is in error This is as a result of the rate selection logic on the RollCall dialogue or the channel is un routed and not all rates are selected Error Red W...

Страница 9: ...as above but for SDI inputs 5 8 Output Status shows the status for the Fiber outputs On the top two lines it shows that SDI I Ps 1 2 and 3 are routed to Fiber O Ps 1 2 and 3 Fiber O P 4 shows E which...

Страница 10: ...et all of the unit s settings to their factory defaults click Factory Defaults NOTE this also clears all of the saved memory settings To reset all of the unit s settings to their factory defaults leav...

Страница 11: ...med to be valid for a particular input If a signal is present on the input but not selected as valid its status will be Error Others is for signals of type other than the above Also because the recloc...

Страница 12: ...ot receiving a valid input signal Primary Input Delay for Rules OK Timer this specifies the time that the Primary Input must be receiving a valid signal in order to be considered OK by any rules Err T...

Страница 13: ...med to be valid for a particular input If a signal is present on the input but not selected as valid its status will be Error Others is for signals of type other than the above Also because the recloc...

Страница 14: ...ot receiving a valid input signal Primary Input Delay for Rules OK Timer this specifies the time that the Primary Input must be receiving a valid signal in order to be considered OK by any rules Err T...

Страница 15: ...ut Fiber Screen The Output Fiber screen shows status associated with the fiber transmitters Fiber Optic Tx 1 8 Shows the fiber transmitter status for each channel SFP Status relates to the product SPF...

Страница 16: ...emory Name field type the new memory name and then click S To return the memory to its default value click the preset button P Use the Recall Memory function to recall the settings saved in a memory l...

Страница 17: ...ameters are made available to logging devices connected to the RollCall Network They are also displayed on a number of RollCall Screens where they can selectively be switched off to prevent them being...

Страница 18: ...IQOTX80 81 82 83 84 99 www snellgroup com Issue 1 Rev 2 2012 Snell Limited Page 18...

Страница 19: ...IQOTX80 81 82 83 84 99 www snellgroup com Issue 1 Rev 2 2012 Snell Limited Page 19...

Страница 20: ...IQOTX80 81 82 83 84 99 www snellgroup com Issue 1 Rev 2 2012 Snell Limited Page 20...

Страница 21: ...prises three columns Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displa...

Страница 22: ...onfiguration for Fiber Inputs 1 4 Config 1 Config 2 INPUT_1_IDENT Fixed input identifier SERIAL IN 1 INPUT_8_IDENT Fixed input identifier SERIAL IN 8 INPUT_1_NAME Editable input name CHANNEL 1 default...

Страница 23: ...1 laser power alarm warning state OK WARN LOW FAIL LOW WARN HI FAIL HI OK OFF blank SFP fit error OUTPUT_8_TX_POWER_STATE Tx SFP 8 laser power alarm warning state OUTPUT_1_TX_POWER Tx SFP 1 laser powe...

Страница 24: ...ork segment code number The second set 10 in the example identifies the enclosure mainframe unit The third set 01 in the example identifies the slot number in the unit The fourth set 99 in the example...

Страница 25: ...ion RollTrack Sending and RollTrack Status display information about the status of RollTracks RollTrack Sending displays the information when the unit is actively sending a RollTrack command No The co...

Отзывы: