IQAES00/01/10/11
N33
IQAES00OPS 27/07/06
www.snellwilcox.com
Version 1 Issue 1
N33.12
RollCall PC Control Panel Screens
Status
Input 1 and 2
This will display various information about the
status of the inputs.
Lock
This indicates the lock status. It may show:
Unlocked
The unit is not locked to the input
Locked
The unit is locked to the input
Sample Rate
This will show the sample rate of the input signal. It
may show:
No Input
No input signal detected
Unknown
The sample rate cannot be
recognized
32, 44.1, 48, 96 kHz
The detected sample rate
PCM
This will show the type of AES input signal. It may
show:
No Input
No input signal detected
PCM
The input is a standard PCM
signal
*Non-PCM
The input is a not a PCM signal
Pro/Con
This will show what sort of input signal has been
detected. It may show:
No Input
No input signal detected
Pro
The signal is a professional type
signal
Con
The signal is a consumer type
signal
CRC Error
In professional mode only this will show the
number of CRC errors (broken framing).
Or
No Input
No input signal detected
CS Mode
In professional mode only this will show the
channel status mode. It may show:
Unknown
2-channel
1-channel
Primary/secondary
Stereo
No Input
No input signal detected
CS Mode Value
This display’s the Channel Status information
(Byte 1, bits 0-3).
Or
No Input
No input signal detected