www.snellgroup.com
Mach HD V2 Motion Compensated Standards Converter with Synchronizer, Up, Down, and Cross Conversion
Version 1 Issue 1
©
Snell 2009
Page 14
Installation
Power Connections
The Mach HD unit has two IEC320 mains power
connectors suitable for a standard IEC type power.
A cable fitted with fused type plug should be used
and a fuse rated at 3A installed.
Supply Voltage
The power supply is auto switching for input
voltages in the ranges of 100 V to 240 V nominal.
No voltage adjustment procedure is required.
CAUTION: THIS UNIT MUST NOT BE
OPERATED WITHOUT
AN EARTH CONNECTION.
Power On/Off Switch
There is no power On/Off switch. The switch on
the front panel is a standby switch.
Power ON will be indicated by the illumination of
the front panel display. Standby mode is indicated
by a red LED on the front panel.
Note that for equipment that is not fitted with a
mains power switch, to comply with EN60950
Clauses 1.7.2 and 2.6.9, the power outlet
supplying power to the unit should be close to the
unit and easily accessible.