14
TIG AC Welding Mode
Basic Setup
•
With High Frequency Start
•
Using On/Off Button
Push the procedure selector switch (Left Hand Down
Arrow). This push-button selects the welding procedure
(MMA of TIG). When selected, one of the following LEDs
lights:
B
,
C
, or
D
Then push the Mode Key
E
(Right Hand Down Arrow).
When selected, one of the following LEDs lights:
F,G,H,L,M,N. Continue to push the button until the
L
LED
lights along with the
G
LED.
L
- LED. TIG welding with arc started with
high frequency.
G
LED. Continuous 2-stage TIG welding
(manual).
Push the
P
– Selector (Right Arrow) until the
Q
–
LED current frequency display lights.
adjusted from 50 – 150 Hz.
Turn the
AA
- Knob watching the
Z
- Display.
Set the current frequency to “60” Hz.
Push the
P
– Selector (Right Arrow) until the
R
– LED
wave balance display lights.
R
- LED
settings, balance = 0; Cleaning from 1-8, Penetration from
1-8.
Turn the
AA
- Knob watching the
Z
- Display.
Set the wave balance to the “0” position.
Push the
P
– Selector (Right Arrow) until the
O
–
LED electrode diameter display lights.
Displays the electrode diameter. The choice of
electrode diameter ranges from 1mm to 4mm.
Turn the
AA
- Knob watching the
Z
- Display.
Set the electrode diameter to the size recommended in
Table “A”. EX.(3/32” = 2.4 mm).
Push the
P
– Selector (Right Arrow) until the
S
– LED slope up display lights.
S
- LED
Slope up. This is the time in which the current, starting from
the minimum, reaches the set current value. (0-10 sec.)
AC TIG WELDING
Push the button until the TIG
D
LED lights
.
Current frequency in
AC
welding mode. Can be
Wave balance in
AC
welding. There are three possible