Troubleshooting
Symptom
Possible Cause
Solution
Remote lock does not respond,
remote lights up
Remote battery low
- Remove and reinstall
remote battery
- Replace remote battery
Receiver module not receiv-
ing power
- Plug AC/DC adapter into outlet and DC jack on rear
of roll cab
- Check blue power LED on AC/DC adapter
- Check connection between DC cord in tool storage
unit (TSU) and receiver module
Remote not paired with
receiver module
- See Remote pairing section
of manual
Remote out of range
- Move closer to TSU
Reset needed
- Unplug and re-plug remote lock cord on back of
ECKO receiver
- Unplug and re-plug remote lock cord on back of
TSU
Self-test start up provides tone
other than 3 rising beeps
Receiver failed self-test
Check sensor board and sensor board cable to
ensure correct assembly. Sensor board should
be connected to main board If damaged, replace
module
Remote does not light up
Remote battery low
- Remove and reinstall remote battery
- Replace remote battery
Response poor or intermittent
Remote battery low
- Remove and reinstall
remote battery
- Replace remote battery
Remote out of range
- Move closer to TSU
Drawer(s) still
unlocked after
locking unit
Drawer(s) not fully closed
before locking
- Drawer(s) not fully closed
before locking
Receiver module speaker sounds
but unit does not lock/unlock
Actuator jammed or not mov-
ing freely
- Push in drawer(s)
- Manually unlock and lock TSU to free lock rod and
actuator
- Unplug and re-plug remote lock cord on back of
ECKO receiver
- Unplug and re-plug remote lock cord on back of
TSU
Sensor board
Sensor board cable
Main board