9
•
EEBc500-int-Z
EnGinE StArt
Follow the instructions for connecting the charger to
1.
the battery and power source in the “Connecting the
Charger” section.
Set the Battery VOLTAGE to 6V or 12V, (24V is not
2.
available).
Set the CHARGE RATE to ENGINE START.
3.
notE:
The charger will supply a 20-amp charge to the
battery before cranking.
Crank the vehicle. The charger will automatically cut out
4.
after a maximum of five seconds.
notE:
During extremely cold weather, or if the battery is
under one volt, charge the battery for five minutes before
cranking the engine.
Wait three minutes before attempting to start again. The
5.
digital display will indicate the time remaining before
cranking again and the ENGINE START LED will be
blinking.
notE:
During this cool down period, the charger is
supplying the battery with a 4-amp charge.
When the digital display times down to
6.
0
and reads
, the ENGINE START LED has stopped blinking and
the CHARGING LED is on, you are ready to crank the
vehicle again.
If the engine still does not start, allow the charger to
7.
charge the battery for five more minutes before cranking
it again.
After the engine starts, unplug the charger power cord
8.
from the wall outlet, before disconnecting from the
battery.
iMPortAnt
– Do not try to start the engine without
a battery in it. You could cause damage to the vehicle
electrical system.
If the engine does turn over, but never starts, there is not
a problem with the starting system; there is a problem
somewhere else with the vehicle. STOP cranking the engine
until the other problem has been diagnosed and corrected.
FLASH rEProGrAMMinG
notE:
Do not attempt to Flash Reprogram a vehicle that
has a discharged or defective battery. Make sure that the
vehicle battery is in good condition and fully charged before
proceeding.
Set BATTERY VOLTAGE to FLASH REPROGRAMMING.
1.
Use “UP” and “DOWN” buttons to adjust voltage to the
2.
voltage needed for the vehicle being programmed (refer
to OEM specifications). Voltage selected is shown on the
digital display. The unit has a voltage range of 13 to 14.8,
with a default of 14.2.
notE
: When the VOLTS LED stops blinking, the display
shows the selected voltage.
Press ON/OFF to activate the output.
3.
notE:
During this time, the other buttons will not work
until you turn off the output. When the display shows
no buttons will work for five seconds, then it automatically
goes back to the default state.
When finished with Flash Reprogramming, press ON/
4.
OFF to exit this mode.
BAttErY PErcEntAGE
Press the display mode button to switch from battery voltage
to battery % of charge.
ALtErnAtor PErForMAncE cHEcK
Set DISPLAY MODE to ALT %.
1.
With vehicle engine running, the digital display will
2.
indicate approximate alternator/battery voltage as percent
of normal (100% is normal). If the percentage is low or
high, a problem is indicated. Use an alternator tester for
further diagnosis.