Page 3-3
CHAPTER 3 CHECKOUT, CALIBRATION AND MAINTENANCE
Effective
09/2005
FUNCTIONS OF HAND SPIN BALANCER
All the service codes are part of P codes. The procedure for activating a P code is described below.
1.
Press the P key, the left window displays letter
“P”
and right window displays current P code number. If the
machine does not activate a P code in this power cycle, it displays a number of
“0”
.
2.
Hold the P key and turn the right knob, the number in right window increases or decreases while operator turns
the pot clockwise or counter-clockwise.
3.
Release the P key when the right number displays the
“P”
code with this corresponding number to activate the
particular P code.
4.
In general, the P code will display some brief information to operator for 1 or 2 seconds, and machine enters the
corresponding function.
In the following paragraph, the functions and operations of various service codes are addressed.
SERVICE CODES
P2
Toggle switch between inch and millimeter display of width.
P3
Toggle switch between gram and ounce display
P4
Toggle Adapter Application
P7
Toggle switch of millimeter and inch for diameter measurement
P12
Read counters
P14
Calibration by user
P18
Enter ALU-S mode (press balancing mode key to exit and back to DYN mode)
P19
ALU-S Single Plane Balancing mode
P20
Toggle Passenger / Motorcycle Tire Balancing mode
P21
Check revision of balancing kernel software
P28
Check last 10 kernel error message
P36
Toggle reading the positions and angles of left and right weights
P43
Read or reset re-setable counter
P44
Read or reset productivity of user. Display counter number of default user only.
P50
Read output voltage of potentiometer of distance measurement of SAPE
P53
Display test
P59
Read resident unbalances of shaft in fine mode. (the fine mode LED indicator is
automatically turn on and off if the machine is in regular accuracy mode)
P64
Read outputs of transducers
P72
Measuring the Phase Shift of the Vibratory System.
P74
Read position and angle of spin shaft
P80
Calibration of SAPE
P83
Manufacture calibration
P84
Empty Calibration of bare shaft
P85
Copy contents of EEP1 to EEP2, only available in initialization.
P86
Copy contents of EEP2 to EEP1, only available in initialization.
P90
Enter match balancing mode
P91
Optimization Balancing
P95
Erase EEProm contents