background image

13

WIRING DIAGRAMS

SE 10 230 VAC, 2-Speed

SE 10 120 VAC, Variable Speed

Содержание SE 10

Страница 1: ...Electronic Air Cleaner MODEL SE 10 OWNER S MANUAL To Place an Order Call ACS Inc 800 878 5030 ...

Страница 2: ...R CORD 10 16 ga with molded grounded plug POWER CONSUMPTION 104 Watts Max AIR HANDLING CAPACITY 90 to 250 CFM WEIGHT HANGING 27 lbs 10 KG SHIPPING 32 lbs 12 KG DIMENSIONS Height Width Length 13 12 171 4 33 cm 30 5 cm 43 8 cm SPECIFICATIONS MODEL SE 10 ...

Страница 3: ...NFORMATION IS PROVIDED FOR TRAINED SERVICE PERSONNEL ONLY VII Periodic Maintenance and Troubleshooting 6 VIll Replacement Parts 8 IX Illustrated Parts 10 Unicell Assembly 12 Wiring Diagrams 13 IMPORTANT NOTICE BEFORE OPERATION PLEASE REMOVE ALL PACKING MATERIAL FROM INSIDE UNIT THIS CAN INCLUDE MARKED TIE DOWN SCREWS CARDBOARD STYROFOAM AND PLASTIC WRAP ON CARBON FILTER MODELS VARY IN MATERIAL USE...

Страница 4: ... claim if any damage is found Before operating unit remove all packing material including carbon afterfilter packaging and unicell shipping screws III HOW YOUR SMOKEETER CRYSTAL AIRE OPERATES The air mover draws air through the ionizer As par ticles pass through the ionizer section they are given an intense positive charge These charged particles are then collected on cell plates The clean air is ...

Страница 5: ... 21 2 from the ceiling for clearance of the unit see Figure 2 WARNING Use fasteners and anchoring devices that will ensure support of the 27 pound unit After the mounting bracket is attached remove the unicell assembly from the cabinet to facilitate handling and lighten the weight see Removing Components page 5 Slide the keyhole slots in the unit base over the studs on the wall bracket and allow t...

Страница 6: ... inside cabinet The unicell and cabinet should be cleaned periodically to assure continued efficiency Cleaning may be required from once a month to once every four months depending on the air quality NOTE The carbon filter cannot be cleaned and needs to be replaced once every six to 12 months 1 The unicell can be cleaned by soaking in a hot solution of SMOKEETER CRYSTAL AIRE brand detergent for 30...

Страница 7: ... baffle plates parallel to the wire are at ground potential Its function is to electrically charge the contaminated particles as they pass through it 3 Unicell Collecting Section the collecting section consists of alternately charged plates Plates are alternately charged with a nominal 5 500 volts DC positive The field between the plates forces the charged particles to the ground plates and remove...

Страница 8: ...t speed control switch on and cautiously engage the safety interlock switch by depressing the button CAUTION Be sure to disengage safety interlock switch after measuring voltages 4 Place the probe s tip on the ionizer and measure the positive DC voltage The voltage should read 10 0 to 11 0 KV DC If measurements are abnormal refer to the troubleshooting guide for cause and correction If measurement...

Страница 9: ...TED AIR SPECIALISTS INC 4440 CREEK ROAD CINCINNATI OHIO 45242 1 800 551 5401 ATTN SMOKEETER CRYSTAL AIRE CUSTOMER SERVICE The following information will be required for prompt service 1 Unit Model No on bottom of base unit at air mover end 2 Unit Serial No on bottom of base unit at air mover end 3 Part No of part see Section IX Illustrated Parts When returning a defective part under warranty you m...

Страница 10: ...lock defective switch 4 Control switch defective 4 Replace control switch D Air mover operates on 1 Control switch defective 1 Replace control switch low or high speed only E Poor air quality 1 Unicell dirty 1 Clean unicell 2 Unicell malfunctioning 2 Check unicell for a Foreign matter between plates b Ionizer wire loose or broken c Defects in insulators 3 Unicell installed 3 Install unicell as sho...

Страница 11: ...10 IX ILLUSTRATED PARTS ...

Страница 12: ...POWER PACK 90 130V 1 21 1246 POWER PACK 200 250V 1 10 30 0537 TINNERMAN NUT 2 11 36 0072 LEAF SPRING INTERLOCK ACTUATOR 1 12 36 0014 CONTACT SPRING COIL 1 13 10 3491 FAN COVER 1 14 32 0156 ALUMINUM PROPELLER 1 15 02 2625 MOTOR ASSEMBLY 1 16 20 1314 LED INDICATOR 1 17 CHOOSE 1 03 1513 SPEED CONTROL VARIABLE SPEED UNITS 1 20 1421 ROCKER SWITCH 2 SPEED UNITS 1 18 20 1368 GROUNDBUS 1 19 20 2922 CORD 1...

Страница 13: ...20 8 9 10 2811 CORNER ANGLE 2 10 02 2721 IONIZER WIRE ASSEMBLY 4 11 36 0037 IONIZER WIRE SPRING 8 12 37 0013 INSULATOR CERAMIC 4 13 30 0039 LOCKWASHER 8 INT TOOTH 8 14 30 0119 SCR PAN HD 8 32x5 16 LG 8 15 18 0795 IONIZER RAIL TOP WITH H V CONTACT 1 16 10 2786 IONIZER RAIL BOTTOM 1 17 37 0064 UNICELL MASK 1 18 30 0283 CELL SPACER WASHER 4 19 20 1312 TERMINAL CELL 1 20 20 1313 TERMINAL IONIZER 1 To ...

Страница 14: ...13 WIRING DIAGRAMS SE 10 230 VAC 2 Speed SE 10 120 VAC Variable Speed ...

Страница 15: ......

Страница 16: ...ot manufactured by UAS THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT As Purchaser s exclusive remedy for any defects in the equipment UAS will exchange or repair any defective parts during the warranty period provided such parts are returne...

Отзывы: