background image

USE OUTDOORS ONLY

 

 

This appliance shall only be used in an above ground open-air situation with natural ventilation, without stagnant 
areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection. 
Any outdoor enclosure in which the appliance is used shall comply with one of the following: 

l       

An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover. 

See Figure 1. 

l       

Within a partial enclosure that includes an overhead cover and no more than two walls. See Figure 2 & 3. 

l       

Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply: 

- At least 25% of the total wall area is completely open; and 
- At least 30% of the remaining wall area is open and unrestricted. See Figure 4 & 5. 

l       

In the case of balconies, at least 20% of the total of the side, back and front wall areas shall be and remain open 

and unrestricted. 

The following diagrams provide a diagrammatic representation of outdoor areas. Rectangular areas have been used in these 
figures - the same principles apply to any other shaped area 
 
 
                                                                                                                 
 
 
 
 
 
 
 

Figure 1 - Enclosure with walls on all sides but                                          Figure 2 - Partial Enclosure with overhead cover and 

 

 

no overhead cover                                                                                                              no more than two walls 

 

                                                             
                                                                                                                           
 
 
 
 
 

Figure 3 - Partial Enclosure with overhead cover and                                      Figure 4 - Open side at least 25% of total wall area.

 

                 

no more than two walls                                                                          30 % or more in total of the remaining wall area is

 

                                                                                                                           

open and unrestricted. 

   
   
 
                                                                                                         

Figure 5 - Open side at least 25% of total wall area. 30 percent

 

or 

more in total of the remaining wall area is 
open and unrestricted

 

 
 
 

Содержание PB304

Страница 1: ...BBQS AND PIZZA OVENS 3 in 1 PORTABLE BBQ USER MANUAL AND INSTALL INSTRUCTION ...

Страница 2: ...al wall area is completely open and At least 30 of the remaining wall area is open and unrestricted See Figure 4 5 l In the case of balconies at least 20 of the total of the side back and front wall areas shall be and remain open and unrestricted The following diagrams provide a diagrammatic representation of outdoor areas Rectangular areas have been used in these figures the same principles apply...

Страница 3: ...ighten all connections before placing the gas cylinder back in its enclosure The gas leak testing procedure should be conducted every time the gas cylinder is refilled and reconnected to the appliance before using the appliance Regulator Connection 1 Check the control knob is in the Off position 2 Make sure the cylinder valve is off 3 Remove the protective cap from the cylinder if present 4 Leak t...

Страница 4: ...lways keep upright Use appliance indoors Modify the constructions of the appliance or the size of any burner injector orifice or any other components Move the appliance during using Obstruct any ventilation of the appliance Allow the flexible gas supply hose or any electrical cord to come in contact with any heated surface of the appliance Use charcoal or any other solid fuel in this appliance Dis...

Страница 5: ... the fuel supply turned OFF at the gas cylinder after each time use DO NOT mistake brown or black accumulation of grease and smoke for paint Interiors of gas bbqs are not painted at the factory and should NEVER be painted Apply a strong solution of detergent and water or use a bbq cleaner with scrub brush on insides of grill lid and bottom Rinse and allow to completely air dry DO NOT apply a caust...

Страница 6: ...orifices are correctly positioned and secured inside the burner inlet We suggest three ways to clean the burner tubes Use the one easiest for you A Bend a stiff wire a light weight coat hanger works well into a small hook Run the hook through each burner tube and burner several times B Use a narrow bottle brush with a flexible handle DO NOT use a brass wire brush run the brush through each burner ...

Страница 7: ...4 The minimum cylinder size for use with this appliance is 9kgs The thread type of this appliance is G1 4B 19 NATURAL HAZARD SPIDERS FACT sometimes spiders and other insects climb into the grill tubes attached to the burners The spiders spin webs build nests and lay eggs The webs or nests can be very small but they are very strong and can block the flow of gas Clean burners prior to use after stor...

Страница 8: ...LY TOOLS REQUIRED Philips screwdriver not included 1 Leg Assembly 2 Temperature gauge assembly No Description Qty 1 Temperature gauge 1 2 Lid 1 3 Cast iron plate 1 4 Pizza Stone 1 5 Cooking grid 1 6 Main body 1 7 Grease tray 1 8 Feet 4 ...

Страница 9: ...3 Pizza grid assembly 4 Cast iron plate assembly 5 Pizza Stone assembly 6 For Grease pan ...

Страница 10: ...6 Clean the fire box bottom 7 Connecting to gas tank 8 For lid ...

Страница 11: ...SMITHS BBQs T A Smiths Cooking Systems P L 3 Barmedman Road Temora NSW 2666 Australia Ph 61 2 69772700 Email info smithsbbq com au ABN 18092300902 www smithsbbqs com au ...

Отзывы: