Troubleshooting
36
3A5578D
E34: Up Button Error
The Up Button or Handlebar Rocker Switch is stuck
or shorted.
Disconnect Handlebar Rocker Switch from
the DCS Control. Clear the error code.
If the error code reappears 30 seconds
after turning the Power Switch back ON,
the problem is the Up Button on the DCS
Control. Check to see if the Up Button is
stuck. If not stuck, replace the Up Button
Switch.
If the error code does not reappear 30
seconds after turning the Power Switch
back ON, the problem is the Handlebar
Rocker Switch. Check to see if the switch
is stuck. If not stuck, replace the Handle-
bar Rocker Switch.
E35: Down Button Error
The Down Button or Handlebar Switch is stuck or
shorted.
Disconnect Handlebar Rocker Switch from
the DCS Control. Clear the error code.
If the error code reappears 30 seconds
after turning the Power Switch back ON,
the problem is the Down Button on the
DCS Control. Check to see if the Down
Button is stuck. If not stuck, replace the
Down Button Switch.
If the error code does not reappear 30
seconds after turning the Power Switch
back ON, the problem is the Handlebar
Rocker Switch. Check to see if the switch
is stuck. If not stuck, replace the Handle-
bar Rocker Switch.
Error
Cause
Solution
Содержание SPS10
Страница 52: ...Parts 52 3A5578D NOTES...
Страница 56: ...Parts 56 3A5578D NOTES...
Страница 57: ...Parts 3A5578D 57 Drive Assembly SPS10 SPS10 DCS Ref Torque 160 170 in lb 18 1 19 2 N m 1 1 1 1...
Страница 61: ...DCS Control Box 18A790 3A5578D 61 DCS Control Box 18A790 SPS10 only...
Страница 63: ...Wiring Diagram 3A5578D 63 Wiring Diagram DCS System 17Y99 17Y23 18A79...
Страница 64: ...Wiring Diagram 64 3A5578D DCS Control Box Powers Display...