Rotor Flashing is a process of magnetizing the Rotor.
This is necessary for the Generator to produce an
output. This is normally done at the factory and
should not be required unless the Generator has
been disassembled.
Should FLASHING become necessary, stop the
engine and identify the two inner and two outer
brush holders. The right hand brush has a wire that
connects to the three terminal rectifier assembly. The
left brush is connected to the inner windings. (See
Fig.8.1).
Connect the 12 Volt Battery’s positive lead to
the left brush terminal. Next, hold the negative lead
to the right brush terminal for a minimum of ten
seconds. This will re-magnetize the Rotor.
12 Volt
Battery
+
-
Facing Stator end with cover removed
Inside
Brush-holder
Outside
Brush-holder
AC
AC
Neg
PROCEDURE 8:
FLASHING THE ROTOR (FOR BALDOR GENERATORS)
Fig. 8.1
Fig. 8.2
ROTOR FLASHING
(FOR WINCO GENERATORS)
To flash the generator assembly, remove the two blue
slide connectors (1 and 2) from bridge (3).
Flash by connecting po) from battery to
positive (+) flag terminal; negative(-) from battery to
AC (Inset, Fig. 8.2).
77
55
1 Neg -
2 Pos +
3 Bridge
1
3
2
+
-
View of Winco generator with end-
bell cover removed
A Winco generator (left) can be distinguished by its yellow stator housing,
whereas the Baldor has either a black or red stator housing (right).
Remove blue negative (1) and
positive (2) flag connectors from
bridge (3).
Connect the positive lead from
battery to the positive flag
connector.
Momentarily touch the negative
lead from the battery to the
negativle flag connector - just long
enough to create an arc.