34
GPP ELECTROFISHER
USER’S MANUAL
2016
Test a single or dual foot switch pedal using an ohmmeter. Carefully
connect the ohmmeter connectors to pins (A & B) on the 4-Pin male
plug. Use care to not allow the ohmmeter connectors to touch when
connecting them to the pins on the 4-Pin male plug. (See Fig.6.1).
The ohmmeter should measure OPEN ohms with the switch off and
ZERO ohms with the switch on. If it does not you may have a broken
wire or a bad switch inside the pedal. If foot switch is inoperative,
return to Smith-Root, Inc. for service. Test dual foot switches with
an ohmmeter using the same method as shown above. Connect the
ohmmeter to pins (A & B) on the 4-Pin connector for switch #1 and to
pins (C & D) for switch #2 (See Fig. 6.1).
• Connect the generator to GPP Control Box.
• Connect the foot switch to GPP Control Box.
• Connect a test load to output cables (see Procedure 9).
A
B
D
C
4-Pin male plug
as seen from end
5 Amp
Fast-Blow
Fuse
Fig. 6.4
PROCEDURE 6:
TEST GPP CONTROL BOX
Smith-Root, Inc.
Generator
Powered
Pulsator
A
B
C
WARNING!
Keep all personnel clear of the Test Load while the
generator is running!
Fig. 6.3
Fig. 6.2
Fig. 6.1
• Switch mode switch to 120 PPS.
• Turn Percent of Range to 50%.
• Switch the output Voltage selector to low range.
• Switch the “Emergency Shutdown Switch” to OFF position (See
Fig. 6.2, A).
• Start the generator.
• Switch the “Emergency Shutdown Switch” to ON position
(See Fig. 6.2, B).
• Press the foot switches.
• The red light (See Fig. 6.2, C) on the front panel should now be
illuminated and the display should show voltage and current
readings.
• If the red light is not illuminated and the display does not show
readings or is black.
• Turn the generator off.
• Check the Fuse on the GPP main circuit board (See Fig. 6.3).
• Replace fuse if blown. A blown fuse may indicate a short in the
Audio Alarm. Disconnect the Audio Alarm (See Fig. 6.4) before
retesting.
Return to start of Procedure 6. If Red light and amp meter
indicates output go to Procedure 7.
PROBLEM: NO OUTPUT FROM GPP ELECTROFISHER (CONT.)