![Smith-Root GPP 2.5 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/smith-root/gpp-2-5/gpp-2-5_user-manual_1305831010.webp)
9
GPP ELECTROFISHER
www.smith-root.com
The average current limits for Warning and Error can be found in the following chart:
2.5 GPP
Frequency
60/120 CPS
60 CPS
30 CPS
15 CPS
7.5 CPS
50-500 V
High Current Warning
5.8
3.4
2.0
1.3
0.8
High Current Error
7.2
4.3
2.6
1.6
1.0
50-1000V
High Current Warning
3.0
1.8
1.0
0.6
0.4
High Current Error
3.7
2.2
1.3
0.8
0.5
5.0 GPP
Frequency
60/120 CPS
60 CPS
30 CPS
15 CPS
7.5 CPS
50-500 V
High Current Warning
11.3
6.8
4.0
2.5
1.5
High Current Error
14.2
8.5
5.1
3.1
1.9
50-1000V
High Current Warning
6.4
3.8
3.4
1.3
0.8
High Current Error
8.0
4.8
4.3
1.7
1.0
7.5 GPP
Frequency
60/120 CPS
60 CPS
30 CPS
15 CPS
7.5 CPS
120/170
High Current Warning
50.0
30.0
18.0
10.8
6.5
High Current Error
62.5
37.5
22.5
13.5
8.1
240/340
High Current Warning
25.0
15.0
9.0
5.4
3.3
High Current Error
31.1
18.8
11.3
6.8
4.1
360/500
High Current Warning
16.6
10.0
6.0
3.6
2.1
High Current Error
20.8
12.5
7.5
4.5
2.7
720/1000
High Current Warning
8.3
5.0
3.0
1.8
1.1
High Current Error
10.4
6.3
3.8
2.3
1.4
9.0 GPP
Frequency
60/120 CPS
60 CPS
30 CPS
15 CPS
7.5 CPS
60/85
High Current Warning
120.0
72.0
43.0
26.0
15.5
High Current Error
150.0
90.0
54.0
32.4
19.5
120/170
High Current Warning
60.0
36.0
21.5
13.0
7.8
High Current Error
75.0
45.0
27.0
16.2
9.7
240/340
High Current Warning
30.0
18.0
11.0
6.5
4.0
High Current Error
37.5
22.5
13.5
8.1
4.9
480/680
High Current Warning
15.0
9.0
5.5
3.3
2.0
High Current Error
18.8
11.3
6.8
4.1
2.5
OPERATING LIMITS