27
smith-root.com
USER'S MANUAL
A. Turn Generator off.
B. Remove foot switch jumper from Procedure 3 from
TS-0 (pins 13 & 15). (Fig. 5.1).
C. Set foot switch control to “Separate”(Fig. 5.2).
D. Switch to “inactive”, the Command Center foot switch
and the Auxiliary foot switch from inside the front
compartment of the console (Fig. 5.3).
E. Start Generator.
F. Close each work deck foot switch circuit (push on
switch).
G. The red light should turn on.
H. Set the foot switch control to “BOTH”.
I. Close both of the bow foot switches at the same time.
J. The red light should turn on.
K. Switch the Command Center foot switch to
“ACTIVE.”
L. Close both of the Work Deck foot switches and the
Command Center foot switch.
M. The red light should turn on.
Foot switch problems can be caused by:
1. Misadjusted switch (try pushing on the switch directly
with your finger).
2. Broken wire (this will need to be traced with an
Ohmmeter).
3. Broken switch (try a jumper across the switch).
4. Incorrect Switch settings.
PROCEDURE #5: TEST BOAT fOOTSWITCH CIRCUITS
Foot Sw
.
Foot Sw
.
GPP
GPP
GPP Control Strip
Foot Sw
.
#1
1
#12
#13
#14
#15
120
VAC120
TS-0
15
13
Fig. 5.1
Fig. 5.2
Fig. 5.3
GPP TROUBLESHOOTING
Содержание ELECTROFISHING BOATS
Страница 1: ...USER S MANUAL ELECTROFISHING BOATS for all SRI H and EH Model Electrofishing Boats ...
Страница 17: ...15 smith root com USER s MANUAL Gas Powered Pulsator GPP OPERATION ...
Страница 32: ......
Страница 33: ...ELECTROFISHING BOATs Standard Boating Rules ...
Страница 42: ......
Страница 50: ......
Страница 52: ......
Страница 53: ......