19
smith-root.com
USER'S MANUAL
GPP OPERATION
12. Adjust the PERCENT OF RANGE switch to achieve
optimum response by the fish. Deactivate the shutdown
switch when switching to HIGH RANGE.
Damage to
the range selector switch may result from switching
under load.
Experimentation will be required to learn
what mode and voltage settings are best for various water
conditions and types of fish.
See charts below:
13. If the ammeter shows LOW RANGE and the RANGE
selector is in the HIGH position, switch to the LOW
Maximum GPP Amperage (2.5 - 5.0)
Model
High
Low
2.5
5.0
8 Amps
16 Amps
4 Amps
8 Amps
7.5
120 V 170 V
62.5 A
31.3 A
20.8 A
10.4 A
240 V
360 V
720 V
340 V
500 V
1000 V
150 A
60 V
85 V
75 A
120 V 170 V
37.5 A
240 V 340 V
18.8 A
480 V 680 V
9.0
Maximum GPP Amperage (7.5 - 9.0)
Model
DC
AC
Amperage
GPP Amperages by Model
position. The low voltage windings on the generator are
capable of delivering more current than the high voltage
windings. If erratic operation occurs in the high range,
switch to the low range. Do not operate the generator
above the power ranges indicated on the meter, or possible
engine and generator damage may occur.
13. If you have been working your GPP hard, run it for
another five minutes under no load before shutting the
generator down. This allows the electrical components to
cool down slowly, extending their life considerably.
14. Turn the fuel valves to the OFF position when the boat is
transported over long distances or on rough roads.
15. Turn the battery switches to OFF when not in use, except
when charging the batteries.
ENGINE & GENERATOR MAINTENANCE
Before cleaning or inspecting, make certain all moving
parts have stopped and cooled down. Do not put hands, feet,
tools or other objects near rotating parts. Always wear eye
protection.
1. CHANGE ENGINE OIL after first five hours of operation.
Thereafter, refer to the OEM maintenance schedule which
can be found in the Generator's OEM Manual.
To drain the engine oil; place one end of a 3/8" dia.
hose on the oil drain and thread the other end through
the transom drain hole. Place the end of the hose onto a
container. Turn the handle on the shut-off valve and let
the oil drain into the container. (Be sure to dispose of the
oil properly). Refill the engine with new oil. Check dip
stick for proper oil level.
2. SPARK PLUG. Clean and reset gap to specs found in
OEM Manual every 100 hours of operation.
3. FUEL. Every 250 hours replace the in-line fuel filter or
clean the bowl.
4. CHECK GUARDS. Operate the generator engine only
with the guards and shields in place and working correctly.
If rotating parts are left exposed they are hazardous.
5. INSPECT GENERATOR BRUSHES after every 100
hours of operation and replace when worn to 3/8 inch
(1cm) or less. Consult Generator's OEM Manual.
Содержание ELECTROFISHING BOATS
Страница 1: ...USER S MANUAL ELECTROFISHING BOATS for all SRI H and EH Model Electrofishing Boats ...
Страница 17: ...15 smith root com USER s MANUAL Gas Powered Pulsator GPP OPERATION ...
Страница 32: ......
Страница 33: ...ELECTROFISHING BOATs Standard Boating Rules ...
Страница 42: ......
Страница 50: ......
Страница 52: ......
Страница 53: ......