6 General maintenance
It is advisable to have your refrigerated service cabinet inspected at least once a year by a
qualified contractor.
This check focuses on:
•
checking along the piping and evaporative cooler for leakage of coolant;
•
examination of the ventilators;
•
checking the function of the thermostat control and the temperature sensors;
•
technical cleaning and removal of dust in the evaporative cooler and the air circulation
system;
•
cleaning and inspection of the drainage system.
Consult with your Smeva dealer about these maintenance schemes.
Magnetic rubber door sealers
The magnetic rubber sealers should be
replaced when damaged or excessively
worn out:
Remove the screws behind the magnetic
rubber sealers.
Door plate with magnetic rubber sealers is
accessible
Replace the magnetic rubber sealers with
a new rubber sealer.
Screw the door plate back on the door.
Drainage connection
The drainage connection has a sliding
coupling sleeve that can be loosened. For
thorough cleaning, or in the event of
blockage, the drainage connection can be
easily separated by loosening the screw
coupling.