background image

 

Refrigerated service cabinet

 

 

v.1.0 

 

 

 

 

1 Introduction 

You have made a good choice by purchasing a Smeva refrigerated service cabinet. The name 
Smeva stands for quality and reliability. 
 
The refrigerated service cabinet is modularly designed; several units can be connected to each 
other. 
 
The refrigerated service cabinet was designed for storing cold products. An evaporative cooler 
device with pipe installation is mounted inside the cabinet. 
 
A compressor unit is situated at some distance away from the cooler it is connected to. The 
connection of the cooler and its periodic maintenance should be carried out exclusively by an 
authorized refrigeration company. The coolant piping, condensation drain and the electrical 
connection are located under the appliance. 
 
The refrigerated service cabinet meets the requirements for being of the highest quality. Despite 
this high quality, the refrigerated service cabinet still needs to be treated and maintained properly. 
The intention of this manual is to assist you with that. 
 
The manual contains the necessary instructions for installation and putting the refrigeration into 
operation, regulation of the thermostat control, cleaning and maintenance, as well as disassembly 
and removal at the end of the product’s life expectancy. 
 
In addition, a troubleshooting list is included for small, easily repaired malfunctions. See Chapter 
8 for more. 
 
For major malfunctions/defects to your refrigerated service cabinet you should contact your 
Smeva dealer. 
 

Содержание SC C3

Страница 1: ...manual Refrigerated service cabinet Smeva BV Address J F Kennedylaan 27 5555 XC Valkenswaard Telephone 040 2073200 Internet www smeva nl Production date June 2011 Specifications of the manual Date Aug...

Страница 2: ...ors The appliance was designed for deep reach in other words it is not suitable for freezing products Cool circuit with evaporative cooler for connection of a remote cooling unit Controlling for tempe...

Страница 3: ...PYRIGHT 2 SAFETY 4 APPLIANCE SPECIFICATIONS 6 1 INTRODUCTION 9 2 INSTALLATION 10 3 PUTTING INTO OPERATION 13 4 THERMOSTAT CONTROL 15 5 CLEANING 17 6 GENERAL MAINTENANCE 20 7 TERMINATION OF USE DISASSE...

Страница 4: ...f contract regarding damage remuneration and guarantee More specifically not observing the safety guidelines can lead to the following damages loss of important functions of the product hazard to peop...

Страница 5: ...s a lift truck forklift crane etc Use suitable equipment for this purpose People carrying out these activities should wear personal safety equipment gloves protective glasses shoes etc and should not...

Страница 6: ...mpartments per door model height 867 mm excl countertop Independent appliance units 1000 1500 2000 2500 and 3000 mm Inside RVS Exterior PVC laminated plate or RVS anti fingerprint RVS AFP Dimensions o...

Страница 7: ...e digital thermostat using a control These options are also available a set of valves in the coolant piping with which the refrigerator can be manually closed for repairs a filter in the coolant pipin...

Страница 8: ...Refrigerated service cabinet v 1 0 8 Electrical specifications...

Страница 9: ...igeration company The coolant piping condensation drain and the electrical connection are located under the appliance The refrigerated service cabinet meets the requirements for being of the highest q...

Страница 10: ...to it on site The refrigerated service cabinet should be placed on a level surface Horizontal Level Adjustable feet Any potential instability caused by play underneath one or more of the adjustable fe...

Страница 11: ...ing face Place both appliance units next to each other Equal height Level Insert M8 threaded ends through the feet Draw the appliance units towards each other by fastening the threaded ends with nuts...

Страница 12: ...pe plate Electrical connections should be executed in accordance with the applicable regulations Before any repair work is carried out on the electrical live parts the power supply to the part involve...

Страница 13: ...et Keep heat sources out of the vicinity of the refrigerated service cabinet Examples are radiators ovens spot lights air curtains Take into consideration that the appliance was not designed for cooli...

Страница 14: ...rection that the doors open is determined beforehand and delivered as such from the factory If the direction of the door opening must be altered contact your Smeva dealer Door handles Always open the...

Страница 15: ...nder the second door from the left behind the transport girder The standard setting of the set point is 0 C Remove the left skirting board and the outer skirting board by loosening the screws Transpor...

Страница 16: ...y 24 hours Depending on the use and the frequency of the doors opening an additional defrost cycle might need to be scheduled on the thermostat regulator The manual defrost function operates via the t...

Страница 17: ...ater Then dry the appliance Never use aggressive cleaners Only use cleaners with a pH degree of acid from 4 to 9 When working on the interior of the appliance one should be aware of potential electric...

Страница 18: ...stains For more severe dirt or stains on RVS AFP see below for further instructions Cleaning RVS AFP severely dirty surface or stubborn stains For stubborn residuals use a non abrasive multifunctional...

Страница 19: ...and the door plate thoroughly Dirt can accumulate and fungus develops Evaporative coolers Clean the exterior of the evaporative coolers with a cloth and warm soapy water Free of dirt Defrosted Do not...

Страница 20: ...n system cleaning and inspection of the drainage system Consult with your Smeva dealer about these maintenance schemes Magnetic rubber door sealers The magnetic rubber sealers should be replaced when...

Страница 21: ...Damages caused by third parties are not covered by the guarantee A few parts are subject to wear and should be replaced during the life expectancy of the appliance When disposing of the refrigerated...

Страница 22: ...efrigeration contractor if you are unable to resolve the problem Partial malfunction If the refrigerated service cabinet only functions partially and you cannot repair this by switching the appliance...

Страница 23: ...laminated block in coated steel housing Steel with a cataphoresis coating and galvanized steel support systems Galvanized steel plastic adjustable feet RVS compartment frames with polypropylene crates...