Refrigerated service cabinet
v.1.0
16
For setting/changing the control, refer to the appropriate manual depending on control that
was chosen following the delivery specifications. The appliance is standardly equipped with
one control unit for each independent appliance unit.
Defrost programme
The evaporative coolers are occasionally defrosted using the ambient air with the ventilators
in operation (natural defrosting). The defrost times are standardly set to 30 minutes once
every 24 hours. Depending on the use and the frequency of the doors opening, an additional
defrost cycle might need to be scheduled on the thermostat regulator.
The manual defrost function operates via the thermostat regulator. For this see the
instructions of the appropriate regulator model type. If this is not available, then move the
cooled goods to a cooled space and turn the appliance off leaving the doors open for a few
hours.
Thermometer display
The temperature indicated is normally the exhaust temperature of the evaporative cooler.
During the defrost cycle the temperature will momentarily increase. This will not affect the
core temperature of the goods during the entire day.