EN
23
6.4 CLEANING THE DRAIN PUMP
Only clean the drain pump if it is obstructed by buttons, hairpins and the like and the water cannot drain.
In this case, proceed as follows.
1. Remove the plug from the socket to disconnect the machine from the electrical power supply.
2. Pull out the base plate. To do this, put your hands
underneath and lever it out.
3. Pull out the drain hose “A”.
Attention: if the hose is hot it means the water is hot
or boiling. Place a tray on the floor and remove the
plug “B” to drain the water.
Depending on the quantity of water, it may be nec-
essary to empty the tray several times.
When no more water comes out, push the hose back
in and screw back the plug “B”.
4. Unscrew the screw “G” with a screwdriver and remove the metal plate “F” which prevents the pump cover
“D” from turning.
Unscrew the pump cover “D” by turning it anti-clockwise.
Clean the pump body and remove any foreign bodies.
Check the inside “E” and make sure the impeller turns freely. If there are any foreign bodies, remove
them.
5. Then screw the pump cover back on.
Position the metal plate “F” so that it prevents the cover from turn-
ing and tighten screw “G” with a screwdriver.
Fix the drain hose by snapping the plug into place «C».
Insert the lower part of the base plate first and then push it towards
the unit until it clicks into place.