28 - INSTALLATION
914779645/B
It is possible to identify the available gas types based on the country the appliance is to be installed
in. Refer to the heading number to identify the correct values in the “Burner and nozzle characteristics
tables".
Burner and nozzle characteristics tables
5 LPG G30/31
G30/31
28-30/37 mbar
•
•
•
•
•
•
G30/31
30/30 mbar
•
•
•
6 LPG G30/31
G30/31
37 mbar
•
7 Town Gas G110
G110
8 mbar
•
•
1 Natural Gas G20 - 20 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
4.2
Nozzle diameter (1/100 mm)
72
97
115
155
Pre-chamber (printed on nozzle)
(X)
(Z)
(Y)
(H3)
Reduced flow rate (W)
400
500
800
1200
2 Natural Gas G20 - 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.8
3.0
4.2
Nozzle diameter (1/100 mm)
72
94
110
145
Pre-chamber (printed on nozzle)
(X)
(Z)
(H8)
(H3)
Reduced flow rate (W)
400
500
800
1200
3 Natural Gas G25.1 - 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.8
3.1
4.1
Nozzle diameter (1/100 mm)
77
100
134
152
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1200
4 Natural Gas G2.350 - 13 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
3.8
Nozzle diameter (1/100 mm)
94
120
165
190
Pre-chamber (printed on nozzle)
(Y)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1200
5 LPG G30/31 - 30/37 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.75
3.0
4.0
Nozzle diameter (1/100 mm)
50
65
85
100
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1300
Rated flow rate G30 (g/h)
73
127
218
291
Rated flow rate G31 (g/h)
71
125
214
286
6 LPG G30/31 - 37 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.9
3.0
4.2
Nozzle diameter (1/100 mm)
50
65
81
95
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
450
550
900
1500
Rated flow rate G30 (g/h)
80
138
218
305
Rated flow rate G31 (g/h)
79
136
214
300
Gas types
IT
GB
IE
FR
BE
ES
PT
RU
SE
DK
FI
NO
PL
HU