IMPORTANT Models equipped with condensers must be supplied with cold water within the
specified temperature range if the condenser itself is to work properly; water hardness must be
< 40°f (21°dh)
BACK PANEL CONNECTIONS
ID
Description
A
Hot water supply hose (red collar)
B
Cold water supply hose (blue collar)
C
Power supply cable
D
Steam condenser drain hose (where applicable)
E
Dishwasher drain hose
F
Peristaltic pump P1 dip tube and P1 tank detergent sensor cable (OPTIONAL)
G
Peristaltic pump P2 dip tube and P2 tank detergent sensor cable (OPTIONAL)
H
Equipotential earthing system.
H
fig. 3 – Diagram, back panel connections and hookup.
The dishwasher is supplied without a power plug, with a cable fitted with pre-isolated terminals.
The electrical hookup to the power supply must use an industrial type plug.
Supplying and installing the plug are the responsibility of the user.
The plug must be rated for the power cable and the electrical specifications of the H07RN-F dishwasher.
CIRCUIT BREAKER
Each appliance must be fitted with a CIRCUIT BREAKER to act as a master switch.
Characteristics of the circuit breaker:
a) Multi-pole: must disconnect all live wires;
b) Easily accessible by the user;
c) Easy to operate (no tools required);
d) Located
nearby the appliance
e) Clearly marked as master switch for the appliance. The appliance is equipped with surge
protection. However, it is advisable to install the following in the electrical cabinet: a dedicated