2.1 Electrical connection
Make sure that the power line voltage matches the specifications
indicated on the rating plate located inside the storage compartment.
This rating plate must never be removed.
If the appliance is connected to the supply by means of a fixed
connection, install a multipolar cut-out device on the line, with
contact opening distance equal to or greater than
3 mm
, located
near the appliance and in an easily reachable position.
Connection to the supply may be fixed or with plug and socket. In
the latter case the plug and socket must be suitable for the cable
employed and conform with the regulations in force.
Regardless of the type of connection, earthing of the appliance is
absolutely obligatory. Before connection make sure that the supply
line is suitably earthed. Avoid the use of reducers, adapters or shunts.
1. For operation on 220-240V~:
use a
three-pole H05RR-F or H05V2V2-F cable
having a cross section of 3 x 2.5 mm
2
(90 cm wide models) or 3 x 1.5 mm
2
(60 cm wide models).
The cable end to be connected to the appliance must be provided
with ground wire (yellow-green) at least 20 mm longer.
7