8
Instructions for the installer
2.2 Gas connection
Use pipe-joint compound made for use with Natural and U.L.P. gas.
This appliance is suitable for installation with Natural
Gas or ULPG (propane). Refer to page 12 for the
relevant burner pressure and appropriate injector
sizes. When the appliance is to be connected to
Natural Gas then the pressure regulator supplied must
be fitted to the gas inlet. A test point (for checking the
gas pressure) is supplied either with the regulator or
as a separate fitting in the case of ULPG (propane) appliances.
Connection of the appliance to the gas supply must be in
accordance with the requirements of AS5601. A
1
/
2
” BSP connector
at the inlet is recommended and the gas supply line to the
appliance must be of adequate length to allow sufficient withdrawal
of appliance for service or disconnection and be:
1. annealed copper pipe or;
2. flexible hose according to AS/NZ1869 & be at least Class
“B”, 10 mm diameter.
The cooker must be installed with provision to allow the gas to be
turned off and disconnected for servicing and removal of the
appliance as required from the gas supply. Before the cooker is
operated make certain all relevant parts are placed in the correct
position.
When the installation is completed the installation connections of
cooker will require to be leak tested, the burner operating pressure
and flame checked and adjusted.
Warranty service calls do not cover these adjustments!
To check the operating pressure of the appliance it is recommended
at least 2 large size burners are used. Ensure appliance is secured
to wall when installation is completed.
N.G. The regulator supplied must be fitted to the
1
/
2
” BSP thread at
the rear of the appliance. An approved manual shut-off valve must
be installed. The N.G. regulator must be checked and adjusted to
1.0kPa after installation.