Erroneous connection could lead to overheati ng of the t erminal board which could lead to blowout an
d
electric shock.
Check that all the connections are tight before connecting the device to the mains.
PE = Yellow/Green: “EARTH”
protection conductor.
N = Blue:
neutral conductor.
L = Brown, Grey, Black:
live conductors
Check there is no static discharge between live and earth
. Check the limit switch continuity between th e
external casing and the earth wire of the
mains. It is advised to u se a multi t ester to carry out thes e
operations.
CABLE SUBSTITUTION
This must be carried out by a qualified authorized technician. The earth wire must always be yellow green.
WARNING: the yellow/green voltage wires in the earth cable must be 3cm longer than the others.
Proceed as follows to connect the power supply wire to the terminal board:
•
( A1 ) Loosen the tops of the cable gland and open the bottom part of the back of the applian ce by
loosening the screws.
•
( A3 ) Loosen the terminal screws and feed the cable conductors through. Take out the old cable from
the cable gland.
•
( A2 ) Feed the new cable through the cable gland. Connect the new cable’s conductors to the terminal
following the connectio n diagram on the label at the lower part of t he back of the appliance. Only