Power Connection Conversion instruction 

Page 9 - 9 

 

ILLUSTRATION 

PROCEDURE 

13.

 

Final check on connections 

. Check that the connections made are mechanically and electrically secure. 
. Use the tester to check the connections made and that they correspond to the electrical wiring diagram. 

 

 

14.

 

Close the appliance: 

. Perform the tests to check the appliance's safety 
following the company procedure. 
. Supply electricity to the appliance. 
. Use the technical application to check that the device's 
inputs and outputs function correctly. 
. Set the type of connection (3=three-phase, 1=single-
phase) in the SET-UP menu, following the procedure 
provided in the user manual. 
. Perform a complete wash cycle including operation of 
the heating elements, to check that the appliance 
functions correctly. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Smeg S.p.A. 

Instruments Division 

Via Leonardo da Vinci, 4 – 42016 Guastalla (RE) Italy 

 

Tel. +39 0522 8211 – Fax +39 0522 821 592 

Customer Service - Instrument Division S39 0522 184 85 95 

 

E-Mail: [email protected] - [email protected] - [email protected] 

 

www.smeg-instruments.com

 

 

Содержание GW0160

Страница 1: ...e units with neutral 400V 3N 7 0kW can be converted on site to the corresponding 230V single phase version 230V 2 8kW The technical data plates of these devices state the two possible electrical conne...

Страница 2: ...rable 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W FUSES 10 3x38 16 A ON POWER SUPPLY L1 L2 L3 In the table the characteristics of the power supply cable supplied with the configurable appliances produc...

Страница 3: ...IRING DIAGRAM Refer to the latest electrical wiring diagram at www smegtech com The section of the diagram involved in this procedure is shown below 2 1 POWER SUPPLY 0160 1160 4060 Default configurati...

Страница 4: ...0160 1160 4060 4190 Power Connection Conversion instruction Page 4 9 2 2 POWER SUPPLY 4190 Default configuration Configurable connection single phase 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W...

Страница 5: ...sides which secure the bottom door 2 Disconnect the earth wire fixed to the left hand corner of the part and pull the door outward 3 Remove the drip guard Undo the fixing screws at the sides Lift up...

Страница 6: ...mponents fuse terminal clamps power supply terminal board voltage change terminal board XCT configuration shown is 400 V 3N 7 The first component to be replaced or adapted by cutting the unused wires...

Страница 7: ...the mains switch SZ Apply the same prescriptions as above Rear view 9 On WD4190 and GW4190 it is necessary to act on the mains switch TERMINALS Mains Switch maintaining in the case of single phase onl...

Страница 8: ...n data plate 230V 1N single phase 230V wiring side L1 and L3 connected to the same terminal clamp L1 L2 and N connect to the same terminal clamp 12 Move the jumpers on the voltage change terminal boar...

Страница 9: ...e Use the technical application to check that the device s inputs and outputs function correctly Set the type of connection 3 three phase 1 single phase in the SET UP menu following the procedure prov...